Design Guide

116 | Wolf Customer Care 800.222.7820
Induction Ranges
Planning Information
Follow all minimum clearances to combustible surfaces
shown in the illustration on the following page.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 50 amps,
and must include 3 or 4 conductors. A 4-conductor cord
is required for installations where grounding through the
neutral is prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit