Design Guide

104
|
Wolf Customer Care 800.222.7820
WOLF OUTDOOR GRILLS
Planning Information
ELECTRICAL
Installation must comply with all applicable electrical codes.
The electrical outlet must be located within reach of the
power cord. A separate circuit, servicing only this appli-
ance is required. A ground fault circuit interrupter (GFCI) is
required to reduce the risk of electrical shock.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type, GFCI
Power Cord 6'
(1.8 m)
GAS SUPPLY
A gas supply line of
3
/4" (19) rigid pipe must be provided to
the outdoor grill or module. If local codes permit, a certied,
3'
(.9 m) long,
1
/2" (13) or
3
/4" (19) ID exible metal appliance
connector is recommended to connect the units
1
/2" NPT
female inlet to the gas supply line.
If the outdoor grill is being connected to a whole house LP
supply, the LP gas pressure regulator is not provided. It
can be purchased from an authorized Wolf dealer. For local
dealer information, visit the nd a showroom section of our
website, wolfappliance.com.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE SYSTEMS OVENS / WARMING DRAWERS