Installation Guide

4 | Wolf Customer Care 800.222.7820
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation. Refer to the illus-
tration below for the minimum power cord plug clearance.
WARNING
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove the ground prong. Do
not use an adapter. Failure to follow these instruc-
tions can result in electric shock, fire, or death.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 4' (1.2 m)
Specifications
Installation Requirements
The drop-down door microwave oven can be installed in a
standard or flush inset application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum ⁄"
(3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24"/30" Model 125 lb (57 kg)
TRIM OVERLAP 24" MODEL 30" MODEL
Top ⁄" (5) ⁄" (5)
Bottom 0" (0) 0" (0)
Sides ⁄" (18) 3⁄" (98)
3"
(76)
MINIMUM CORD
CLEARANCE
RATING PLATE
Power cord clearance
Rating plate location