Specifications

Ventilation Recommendations 108
Ventilation recommendations on the following pages
provide CFM recommendations and blower options for
each ventilation hood and downdraft.
Refer to the illustrations below for dimensions of Wolf in-
line and remote blowers. Installation instructions shipped
with each Wolf ventilation product provide detailed specifi-
cations. These instructions can also be found on our
website, wolfappliance.com/specs.
Blower Assemblies
For Wolf ventilation hoods and downdrafts that do not
include a blower assembly, an internal, in-line or remote
blower assembly must be selected to accommodate the
cooking appliance, CFM requirements and homeowner
preferences. Inter nal, in-line and remote blowers are
available through your authorized Wolf dealer. For local
dealer information, visit the find a showroom section of our
website, wolfappliance.com.
24
1
/2
"
(622)
15
1
/2
"
(394)
28
1
/4
"
(718)
20
3
/4
"
(527)
24
3
/4
"
(629)
14"
(356)
4
3
/4
"
(121)
10" (254)
Diameter
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
18" (457)
22"
(559)
10
1
/8
"
(257)
7
1
/4
"
(184)
10"
(254)
10" (254)
Diameter
1200 CFM
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
21" (533)
25"
(635)
10
3
/8
"
(264)
7
1
/4
"
(184)
10"
(254)
10" (254)
Diameter
1500 CFM
11
3
/4"
(298)
21
1
/2"
(546)
24
3
/8"
(619)
18
1
/2"
(470)
12
1
/4"
(311)
4
1
/2"
(114)
In-Line Blowers
600 CFM
18"
(457)
22"
(559)
24
7
/8
"
(632)
12"
(305)
18"
(457)
8"
(203)
1100 CFM
Remote Blowers
600 CFM AND 900 CFM