Ventilation Guide
wolfappliance.com
|
11
Step 2: Determine the CFM
Ventilation performance is measured in cubic feet per
minute, or CFM. The chart below provides CFM recommen-
dations specic to the Wolf cooking appliance and ventila-
tion system used. To maximize airow and performance,
specify a blower to match or exceed the CFM listed.
Additional CFM may be required for long duct runs and
ranges or rangetops with a charbroiler or griddle. When
determining the proper CFM for your installation, take into
consideration the equivalent duct length calculated on the
previous page.
IMPORTANT NOTE: Consult a qualied HVAC professional
for specic applications.
Step 3: Select a Blower
All Wolf ventilation products are shipped without the blower
assembly. An internal, in-line or remote blower must be
selected to accommodate the cooking appliance and ven-
tilation product. Wolf ventilation products must be installed
only with a Wolf blower.
Wolf blower assemblies are available through an autho-
rized Wolf dealer. For local dealer information, visit the nd
a showroom section of our website, wolfappliance.com.
Installation instructions shipped with each blower provides
detailed specications.
Charts on the following pages provide internal, in-line and
remote blower options for all Wolf ventilation products.
DETERMINE THE CFM
WOLF PRODUCT CFM
MODEL COOKTOP HOOD DOWNDRAFT PRO HOOD
COOKTOP / MODULE
CI152T/S CE152T/S 215 150 215
CT15G/S MM15T/S IM15/S 215 150 215
IG15/S IS15/S IF15/S 215 215
CI243C/B 450 500
CI304T/S CE304T/S 450 350 500
CI304C/B CE304C/B 450 500
CG304T/S CG304P/S 450 350 500
CI365T/S CE365T/S 600 500 500
CI365C/B CE365C/B 600 500
CG365T/S CG365P/S CG365C/S 600 500 500
DUAL FUEL RANGE
DF304 500
DF366 DF364C DF364G 900
DF486C DF486G DF484CG DF484DG DF484F 1100
DF606CG DF606DG DF606F DF604CF DF604GF 1500
GAS RANGE
GR304 500
GR366 GR364C GR364G 900
GR488 GR486C GR486G GR484CG GR484DG 1100
GR606CG GR606DG GR606F 1500
SEALED BURNER RANGETOP
SRT304 500 500
SRT366 500 900
SRT364C SRT364G 900
SRT486C SRT486G SRT484CG SRT484DG SRT484F 900
CFM are based on the cooking appliance output. 1 CFM per 100 Btu (.03 kW) recommended.