Design Guide

wolfappliance.com | 101
21" (533)
BEHIND FRAME
5
1
/2"
(140)
DRAWER
FULL
EXTENSION
17"
(432)
23
1
/2" (597)
7
/8"
(22)
Dimensions
VACUUM SEAL DRAWER
DRAWER FRONT W
24" Drawer Front 23⁄" (597)
30" Drawer Front 29⁄" (759)
5
1
/2"
(140)
W
DRAWER FRONT
Planning Information
The vacuum seal drawer can be installed in a standard or
flush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum ⁄"
(3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Vacuum Seal Drawer 75 lb (34 kg)
TRIM OVERLAP
Top 0" (0)
Bottom 0" (0)
Sides ⁄" (18)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 10 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 3' (.9 m)