Design Guide

114 | Wolf Customer Care 800.222.7820
Induction Ranges
Planning Information
Follow all minimum clearances to combustible surfaces
shown in the illustration on the following page.
IMPORTANT NOTE: Adjacent countertops must be at least
35⁄" for flush installation to the top of the unit.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
If a power supply cord is being used with models that
require a 50 amp breaker, the cord must be designated for
use with ranges and rated for 240/208, 50 amps and must
include 3 or 4 conductors. A 4-conductor cord is required
for installations where grounding through the neutral is
prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit