Design Guide

wolfappliance.com | 139
RECIRCULATING APPLICATION
The ceiling-mounted hood with an internal blower only,
can be installed in a recirculating application. The air dis-
charge must be a minimum of 40"
(1016) from every side of
the hood. Refer to the illustration below. The ductwork and
vent cover are not provided. A recirculation kit, available
through an authorized Wolf dealer, is required.
Planning Information
Installation of the ceiling-mounted hood should be 36"
(914) to 84" (2134) from the bottom of the hood to the
countertop.
The hood can be operated using the remote control or the
control panel located on the right side of the hood.
The hood is shipped without a blower assembly. Inter-
nal, in-line, and remote blowers are avail able through an
authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com. Refer to Ventilation Suggestions on
pages 156–159.
Ceiling-mounted hoods include a 6"
(152) round discharge
for internal blowers and a 10"
(254) round discharge for in-
line and remote blowers. For an internal blower, the blower
box can be rotated to discharge right, left, front, or rear.
For an in-line or remote blower, the discharge is vertical
only.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.
40"
(
1016
)
MIN
Recirculating application
Cooktop Ventilation Hoods