Pro Wall Hoods IG

8 | Wolf Customer Care 800.222.7820
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustration
below. A separate circuit servicing only this appliance is
required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
E
6"
(152)
5"
(127)
30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP
Electrical location
Rating plate location
RATING PLATE
Hood Preparation
Remove the lters, spacers, and grease cup(s) prior to
installation.
To remove the lters, press upward, then rotate the bottom
downward. To remove the spacers, slide the spacer toward
the center of the hood slightly. Press upward and rotate the
bottom downward. To remove the grease cup(s), lift verti-
cally to remove from the rear ange. Refer to the illustrations
below.
SPACER
Filters
Spacer
GREASE
CUP
FLANGE
Grease cup