Installation Guide

wolfappliance.com | 5
Installation Requirements
Install the hood 30" (762) to 36" (914) from the bottom of
the hood to the countertop.
BLOWER ASSEMBLIES
Pro Wall Hoods require an internal, in-line, or remote
blower assembly, avail able through an authorized Wolf
dealer. For local dealer information, visit the find a show-
room section of our website, wolfappliance.com. Refer to
specific installation instructions provided with each blower
assembly.
For internal blowers, install the blower prior to mounting
the hood.
HORIZONTAL DISCHARGE
Pro Low-Profile Wall Hoods have an adjustable discharge.
Pro Wall Hoods that are 24"
(610) and 27" (686) deep have
a vertical discharge. A horizontal discharge kit is avail able
through your authorized Wolf dealer. For local dealer infor-
mation, visit the find a showroom section of our website,
wolfappliance.com.
DUCT COVER
Optional stainless steel duct covers, in multiple heights, are
available through your authorized Wolf dealer. Duct covers
must be attached to the hood prior to hood installation.
For local dealer information, visit the find a showroom sec-
tion of our website, wolfappliance.com.
RECIRCULATING APPLICATION
Pro Wall Hoods in 30" and 36" widths with an internal
blower (600 CFM or less), can be used in a non-ducted
application with a recirculating filter. A recirculation kit,
available through an authorized Wolf dealer, is required.
For local dealer information, visit the find a showroom sec-
tion of our website, wolfappliance.com.
Specifications