Installation Guide

8 | Wolf Customer Care 800.222.7820
INSTALLATION
Electrical Connections
WARNING
Before making electrical connections, verify the power
is turned off at the service panel.
IMPORTANT NOTE: Refer to installation instructions pro-
vided with the blower assembly.
INTERNAL BLOWER
1 Connect black to black and white to white with the
provided connectors, and connect the green/bare wire
to the ground screw.
2 Verify all wires are secure and not pinched, and reinstall
the box.
3 Plug the blower power cord into the receptacle inside
the hood. Refer to the illustration below.
4 Turn on the power to the hood and verify light and
blower operation.
IN-LINE/REMOTE BLOWER
1 Remove the connector from the end of the orange wire.
2 Connect the home supply. Connect black to black and
connect the green/bare wire to the ground screw.
3 Connect the blower supply. Connect black to orange,
all three white wires, and connect the green/bare wire to
the ground screw.
4 Verify all wires are secure and not pinched, and reinstall
the box.
5 Turn on the power to the hood and verify light and
blower operation.
RECEPTACLE
ELECTRICAL
BOX
Electrical connections
ELECTRICAL
BOX
Electrical connections