Design Guide

154 | Wolf Customer Care 800.222.7820
RECIRCULATING APPLICATION
The hood can be installed in a recirculating application.
Refer to the illustration below. Ductwork is not provided.
Recirculating lters, available through an authorized Wolf
dealer, are required.
COOKTOP VENTILATION
Planning Information
The under-cabinet hood insert should be installed 24" (610)
to 36"
(914) from the bottom of the hood to the countertop.
The hood can be operated using the remote control or the
control panel located at the front of the hood bottom.
The hood requires a 300 or 600 CFM internal blower, avail-
able through an authorized Wolf dealer. For local dealer
information, visit the nd a showroom section of our
website, wolfappliance.com. Refer to Ventilation Sugges-
tions on pages 172–175. The hood includes a 6"
(152) round
discharge for an internal blower.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
HORIZONTAL
DISCHARGE
DISCHARGE
ABOVE CABINET
Recirculating application