Specifications

9
An ongoing program of product improvement may require us to change
specifications without notice. RFG, RFG-W (EXT) Revised May 2010
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free (800) 988-8103
Tel (360) 650-1111
Fax (360) 650-1166
Info@www.woodstone-corp.com or visit www.woodstone-corp.com
Bistro Installation and Operation Manual
INSTALLATION CLEARANCES
a. The Wood Stone Bistro oven should have a minimum 1-inch clearance to combustibles from all sides, 6-inch
clearance to combustibles from the top, and 6-inch clearance from the exhaust transition and flue collar. If building
a facade that will contact the oven, use completely non-combustible materials. Any facade wall built above or 6 inches to
either side of the doorway must be of non-combustible construction. Please note that standard drywall (or sheet rock)
is considered a limited combustible. Any walls perpendicular to the front of the oven in the area 30 inches to either
side of the doorway and 36 inches in front of the oven should have a non-combustible surface.
b. This oven should be installed on a non-combustible floor surface. The non-combustible floor surface must extend
36-inches in front of and 30-inches to either side of the oven doorway.
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS OVEN
BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
WARNING: Installation and servicing of this product could expose you to glasswool/ceramic
fibers as well as Calcium Silicate dust. ALWAYS WEAR RESPIRATORY AND EYE PROTECTION
WHEN INSTALLING OR SERVICING THIS APPLIANCE. Please read this entire manual before you
install the oven. Failure to follow instructions may result in property damage, bodily injury
or even death. Contact your local building or fire officials about restrictions and installation
inspection in your area.
!
InstallatIon clearances
Hatched area must
be left accessible and
unobstructed after
installation for air intake
and routine service of
the oven burner.
1-inch minimum
side clearance
to combustible
construction
Maintain 6-inch
clearance from
the exhaust
transition.
6-inches
6 inches
CLEARANCES
!
WARNING: Do Not pack required air space (clearance) with insulation or other materials.
When non-combustible building materials contact the body of the oven, the clearances to
combustibles are transferred to those non-combustibles.