GAS SPECIFICATIONS
Model SV-1 SV-2
WS-MS-4-RFG-IR-NG
3�5" 5"
WS-MS-5-RFG-IR-NG
3�5" 4�75"
WS-MS-6-RFG-IR-NG
3�5" 4�75"
WS-MS-7-RFG-IR-NG
3�5" 4�6"
Model SV-1 SV-2
WS-MS-4-RFG-IR-LP
9" 7"
WS-MS-5-RFG-IR-LP
9" 8"
WS-MS-6-RFG-IR-LP
9" 8"
WS-MS-7-RFG-IR-LP
9�2" 9�5"
The Wood Stone Gas ovens are equipped with a 3/4" NPT gas connection located at the rear left of the oven� Have a
licensed gas installer provide the hook-up and test all fittings and pipe connections for leaks� Use approved gas leak
detectors (soap solutions or equivalent) over and around the fittings and pipe connections� DO NOT USE FLAME TO
TEST FOR LEAKS!
SV-1 is the gas control valve that operates the Underfloor Infrared (IR) burner� The manifold pressure test port is 1/8: NPT
pugged tap located on the IR burner manifold�
SV-2 is the gas control valve that operates the interior radiant burner� SV-2 is located at the rear left beneath the oven�
The manifold pressure test port for the radiant burner is a 1/8" NPT plugged tap located at the base of the T-junction
between the SV-2 and the radiant/interior burner�
NOTE: Gas valves are shipped in the ON position�
The burner manifold pressure has been adjusted and tested at the factory� A variety of factors can influence this pressure,
so be sure to test the burner manifold pressure and adjust the valve as necessary to achieve the specified pressure�
NOTE: Maximum inlet gas pressure: 1/2 psi (14 inches W.C.)
This oven requires no modifications or adjustments for use at high altitudes.
Factory specified individual burner manifold pressures (W.C.) for RFG-IR models equipped to burn
Natural Gas (NG)
Factory specified individual burner manifold pressures (W.C.) for RFG-IR models equipped to burn
Propane (LP & HLP)
Model SV-1 SV-2
WS-MS-4-RFG-IR-HLP
9" 7"
WS-MS-5-RFG-IR-HLP
9" 8"
WS-MS-6-RFG-IR-HLP
9" 8"
WS-MS-7-RFG-IR-HLP
9�2" 9�5"