VENTING
The following are the manufacturer’s recommendations for venting the Wood Stone MS (Mountain Series) RFG-IR ovens�
It is never appropriate to use “B vent” in any part of an exhaust system connected to a Wood Stone oven� All duct material
must be manufactured to the specifications of a
grease duct� Submit your venting plans to your local authorities before
proceeding with your installation, as there may be additional requirements in your area� All non-solid fuel venting systems
should be inspected and cleaned at least every 3 months�
There are three venting options�
VENTING OPTION 1
Direct Connection: A Listed building heating appliance chimney, also listed as a grease duct as described in NFPA 96,
connected directly to the oven flue collar and provided with a power ventilator listed for restaurant appliance exhaust�
The power ventilator should be rated for a minimum of 300 °F� Wood Stone does not recommend the use of an in-line
fan� A field built grease duct, constructed and installed to the specifications of a grease duct as detailed in NFPA 96 or
the International Mechanical Code, may also be used�
A static pressure of -0�1 inches water column is necessary at the oven flue collar to ensure that flue gas temperatures
do not exceed 300 °F at the fan inlet� This measurement may be taken by inserting the probe of the magnahelic gauge
through the oven doorway, upwards to the oven flue collar� NOTE: Double door ovens (models ending in “-DD”), have two
flue collars� Both must be connected and a static pressure of negative 0�1 inches must be maintained at each collar� See
table below for CFM required to attain the specified static pressure�
CFM REQUIREMENTS
Model CFM required
WS-MS-4-RFG-IR 400
WS-MS-5-RFG-IR 450
WS-MS-6-RFG-IR 450
WS-MS-7-RFG-IR 450
Model Oven Flue Collar I.D. (nominal)
WS-MS-5 Mt� Adams 10 inch
WS-MS-6
Mt� Baker 10 inch
WS-MS-7
Mt� Rainier 10 inch
Collar I.D.
Flue adapter
Install the venting system in accordance with the duct
manufacturer’s instructions and in accordance with all local codes�
All field built components should be built to the applicable codes
and standards and are subject to the approval of the authority
having jurisdiction�
NOTE: If your MS-5, MS-6 or MS-7 oven is ordered from Wood Stone without a hood, it will have a round flue adapter
installed to facilitate direct connection to a round duct� If the oven is to be installed under a hood, it MAY be necessary
to remove the round adapter to properly position the hood� This is done by removing the screws that attach the adapter
to the oven� Please contact Wood Stone if you have any questions�
NOTE: MS-4 ovens come standard with a round 8" O.D. collar
and do not require the flue adapter for a direct connection.