TROUBLESHOOTING GUIDE
Hearth Temperature is above the
Hearth Set Point�
This is normal� Radiant (dome) flame can drive the temperature over
the Hearth Set Point� The Hearth Set Point only controls the underfloor
(hearth) IR burnerTurn down the dome flame if needed�
Underfloor IR burner did not fire when the floor temperature dropped below
the Hearth Set Point� Contact Wood Stone for assistance�
Hearth temperature is above the Hearth Set Point�
Please contact Wood Stone at 1-800-988-8103 should service be necessary, or if you have any questions about
your oven. Our service hours are 8am to 4:30pm Pacific Time. Follow the recorded instructions for Emergency
Service if you require assistance during non-business hours. A Wood Stone technician will promptly respond
to your call.
“Chec” display on Controller
Controller will not turn on
1.
Incoming power to oven turned off� Check circuit breaker for circuit
supplying the oven� Check that any wall switches external to the oven
that control oven power are turned on� Check that any interlocks
external to the oven are turned on�
2. If Controller still does not turn on, please contact Wood Stone for
assistance�
Radiant flame does not light 1. Is gas turned on to the oven? Is gas shut-off valve turned all the way
on?
2. Debris in burner� Burner may require cleaning� Contact Wood Stone for
assistance�
3. Damaged igniter or gas valve� Contact Wood Stone for assistance�
If the oven is being started for the first time:
Has all air been bled from the gas line?
Is the switch on the SV-2 valve in the ON position?
NOTE: Valve is located beneath the oven at the rear, towards the side
where the radiant burner is located�
Underfloor burner is not running�
“Hearth Heat” light is off�
PROBLEM CAUSE/SOLUTION