GAS SPECIFICATIONS
Model SV-2
WS-MS-4-RFG-W-NG
5”
WS-MS-5-RFG-W-NG
4�75"
WS-MS-6-RFG-W-NG
4�75"
WS-MS-7-RFG-W-NG
4�6"
Model SV-2
WS-MS-4-RFG-W-LP
7"
WS-MS-5-RFG-W-LP
8"
WS-MS-6-RFG-W-LP
8"
WS-MS-7-RFG-W-LP
9�5"
The Wood Stone Gas ovens are equipped with a 3/4" NPT gas connection located at the rear left of the oven� Have a
licensed gas installer provide the hook-up and test all fittings and pipe connections for leaks� Use approved gas leak
detectors (soap solutions or equivalent) over and around the fittings and pipe connections� DO NOT USE FLAME TO
TEST FOR LEAKS!
SV-2 is the gas control valve that operates the interior radiant burner SV-2 is located at the rear left beneath the oven�
NOTE: The gas valve is shipped in the ON position�
The manifold pressure test port for the radiant burner is a 1/8" NPT plugged tap located at the base of the T-junction
between the SV-2 and the radiant/interior burner
The burner manifold pressure has been adjusted and tested at the factory A variety of factors can influence this pressure,
so be sure to test the burner manifold pressure and adjust the valve as necessary to achieve the specified pressure�
NOTE: Maximum inlet gas pressure: 1/2 psi (14 inches W.C.)
This oven requires no modifications or adjustments for use at high altitudes.
Factory specified individual burner manifold pressures (W.C.) for RFG-W models equipped to burn
Natural Gas (NG)
Factory specified individual burner manifold pressures (W.C.) for RFG-W models equipped to burn
Propane (LP & HLP)
Model SV-2
WS-MS-4-RFG-W-HLP
7"
WS-MS-5-RFG-W-HLP
8"
WS-MS-6-RFG-W-HLP
8"
WS-MS-7-RFG-W-HLP
9�5"