8
INSTALLATION CLEARANCES
THE FOLLOWING CLEARANCE INFORMATION APPLIES TO ALL
WOOD STONE MOUNTAIN SERIES OVENS
1" side clearance to combustible
building materials.
14" top clearance to combustible
building materials.
Any facade materials 6” to either side of
the doorway and above must be NON-
COMBUSTIBLE.
Note: 0" side and top clearance to non-
combustible materials. However, the
respective clearances to combustibles
are transferred to those non-
combustibles.
14"
Combustible building material
Non-combustible building material
Any facade wall 6” to either side of the
oven doorway and above MUST be of
non-combustible construction with no
exceptions�
For use only on noncombustible floors
(installér sur un plancher incombustible
seulement). Non-combustible floor
surface AND provided with a non-
combustible floor covering at least 30"
to each side of, and 36" in front of the
door opening.