Specifications

13
An ongoing program of product improvement may require us to change
specifications without notice. (-W). Revised September 2009
Wood Stone Corporation
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free (800) 988-8103
Tel (360) 650-1111
Fax (360) 650-1166
Info@woodstone-corp.com or visit www.woodstone-corp.com
Mountain Series Installation and Operation Manual
temperature readout
The temperature sensor (thermocouple) is factory mounted in the ceramic
floor of the oven. The thermocouple cable runs through flexible conduit and
is factory connected to the thermometer readout which is mounted to the
stand of the oven. Extra conduit is provided to allow the thermometer box
to be mounted to the oven facade instead or to the oven if so desired.
Location of digital readout
Digital Readout
Incoming 120 VAC circuit
(or optional 240 VAC circuit)
attaches here. Ground to
the green screw in the rear
inside wall of the stainless
steel enclosure.
120V/12V Class
II transformer (or
240V/12V Class II
transformer
NOTES:
Be sure that the face plate is •
replaced right-side-up.
There is no need to disconnect •
the conduit when relocating the
digital readout.
The mounting brackets for the •
stainless steel digital readout
enclosure can be removed and
remounted to accommodate the
needs of various installations.
Take care not to pull on the •
conduit or thermocouple wires.
Thermocouple wires
(factory installed)
12V
TC
+ -
IMPORTANT NOTE: If enclosing the oven in a facade, you must leave an access panel to allow for service of the
thermocouple. Wood Stone's oven mounted wood box has an access panel built in.
Wood Stone does not supply an electrical power cord. The power cord or direct connection is to be supplied by
others and connected by a licensed electrician.
TO MAKE THE ELECTRICAL CONNECTION TO THE THERMOMETER READOUT:
Remove the (4) screws holding the stainless steel faceplate to the readout box and gently pull back the faceplate.
The standard oven model comes configured for connection to a 120 VAC circuit. The oven can be ordered
configured for connection to a 240 VAC circuit. Have a licensed electrician install the appropriate circuit through
the vacant hole in the back of the stainless steel readout enclosure. Attached to the backside of the faceplate
is the readout and a 120/12V (or 240/12V) step down transformer. Connect the incoming power supply to the
transformer primary leads. Ground the incoming power supply using the green screw on the rear inner wall of
the stainless enclosure.
DIGITAL TEMPERATURE READOUT