StuCCo FiniSh appLiCation
INSTALLING THE WOOD STONE 'S' MODEL (STUCCO FINISHED)
WOOD-FIRED OVEN
MINIMUM STUCCO APPLICATION IS 1"
TRADITIONAL
STUCCO MIX
1 part masonry cement
1 part regular cement
5 parts sand
STUCCO PREMIX IS
PROBABLY AVAILABLE
AT YOUR LOCAL
LUMBER YARD
OR BUILDING SUPPLY
STORE
1 part premix
2 parts sand
This figure depicts the application of stucco on a Wood Stone oven. Use no less than one inch of
stucco coating to cover all exposed metal lathing on the oven. Maintain a minimum of 36" clearance
from top and sides of oven to all combustible surfaces.
STUCCO FINISH APPLICATION