inStaLLation CLearanCeS
e. If the space between the legs of the stand is used for wood storage, it is recommended that it be a covered container
or box to prevent the possibility of sparks or embers from making contact with the stored wood. An 8-1/2" (eight and
one-half inch) air space clearance is required between the bottom of the oven and any wood storage container.
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS OVEN BE
INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
Please read this entire manual before you install the oven. Failure to follow instructions may result in
property damage, bodily injury or even death. Contact your local building or fire officials about restrictions
and installation inspection in your area.
CLEARANCES
c. Install this oven only on a non-combustible floor surface. The non-combustible floor surface should extend 36" out in
front of the oven, and extend 30" to either side of the oven doorway.
a. The Wood Stone ovens are (per ETL listings) approved for 1" clearance to combustibles on the sides and back of the
unit. Any combustible facade or surround installed around the oven must maintain a 1" air space between it and the outer
shell of the oven. An air space of 14" is required between the top of the unit and any combustibles.
b. WARNING: DO NOT PACK REQUIRED AIR SPACE WITH INSULATION OR OTHER MATERIALS. The oven is fully
insulated at the factory and requires no additional insulation.
NOTICE: FOR STUCCO COVERED OVENS (MODEL NUMBERS ENDING IN 'S'), 36” CLEARANCE TO
COMBUSTIBLE BUILDING MATERIALS IS REQUIRED. *When non-combustible building materials contact the body
of the oven, the clearances to combustibles are transferred to those non-combustibles.
!
WARNING: Installation and servicing of this product could expose you to glasswool/ceramic
fibers as well as Calcium Silicate dust.
ALWAYS WEAR RESPIRATORY AND EYE PROTECTION
WHEN INSTALLING OR SERVICING THIS APPLIANCE
. Please read this entire manual before you
install the oven. Failure to follow instructions may result in property damage, bodily injury
or even death. Contact your local building or fire officials about restrictions and installation
inspection in your area.
d. Any facade above the doorway of the oven and 6" to either side of the doorway must be constructed of
non-combustible building materials such as metal, plaster, tile, etc.
f. When utilizing a combustible material to construct the enclosure, all openings within 30" of either side of the door
opening, floor to ceiling, must be sealed to prevent the entry of sparks or embers. Wood-fired ovens must be installed
on non-combustible floor surface AND provided with a non-combustible floor covering at least 30" to each side of door
opening and 36" in front of the door opening.
INSTALLATION CLEARANCES