Product Overview

Correct installation requires downward pitch.
Automatically drains with hose removed.
Incorrect installation traps water in the tube.
Hose left on faucet during freezing weather prevents
the water from draining out of the faucet. Thus, the
water will freeze and the tube may burst.
Frozen split
tube condition
Water drains out of faucet
when water is shut off
Water shut-off valve is located here
How a Standard Frost-Proof Faucet Works
The product is designed to be frost-proof when installed properly (with a slight downward pitch) and there is no restriction on
the hose nozzle to prevent the faucet from draining. If a hose is attached during freezing weather, water is trapped inside the
faucet which may cause the faucet to freeze and burst.
WARNING - Faucet must be
installed with downward pitch
toward nozzle and hose must
be removed in freezing weather
or faucet may freeze and burst.
Not intended for continuous use
applications.
The warning (left), that the product needs to be installed
with a downward pitch, facilitates the draining of the
water once the unit is turned off. Also indicated is the
warning that the hose must be removed in freezing
weather or the faucet may freeze and burst.
Adjustable wall ange (right) displays
REMOVE HOSE OR FAUCET MAY FREEZE AND BURST”
Hose
Attached
Freezing
Begins...
Pressure
within tube
builds...
Tube integrity
lost. Bursting
occurs...
THE ONLY POSSIBLE CAUSE OF THE BURSTING OF THE TUBE IS AN OBSTRUCTION SUCH AS A HOSE
BEING LEFT ON IN FREEZING CONDITIONS OR THE IMPROPER INSTALLATION OF THE PRODUCT
THAT PREVENTS THE WATER FROM DRAINING AFTER THE VALVE IS SHUT-OFF.
The faucet above is shown with the valve in the closed position. The water is shut off several inches into the home. The
water line does not freeze because of the heat in the home. The product cannot freeze because there is no water in the
faucet. When the valve is turned off, all of the water in front of the valve drains from the faucet leaving the tube empty. Also
shown is correct and incorrect installation and a frozen split tube condition when hose is left on during freezing weather.
When a hose or other restriction is left attached, the water cannot drain from the faucet properly. As the temperature drops
below freezing, the water in the faucet begins to freeze. The freezing conditions are applied from the outside of the house
back toward the interior as the water continues to freeze. Once the water has frozen into the faucet itself, if the faucet
has been shut off, there is no relief from this expanding pressure. Eventually the copper tubing will burst to relieve the
pressure. No noticeable damage is visible in the home at this time. Only a few drops of water will leak through this bulge at
the time of the bursting. Once the weather warms, the ice in the faucet will melt. Since the burst in the tubing is after the shut
off valve, water will not leak out of the burst tubing until the water is turned on. Thus, there can be a considerable amount of
time between the actual rupture of the tubing and the discovery of the problem.
©2015 WOODFORD Mfg.
Rev 04/15 Form No. works.104
For more information contact…
WOODFORD MANUFACTURING COMPANY
2121 Waynoka Road, Colorado Springs, Colorado 80915 • Phone: (800) 621-6032 • Fax: (800) 765-4115
To view our complete product line visit: www.woodfordmfg.com or email: sales@woodfordmfg.com
A Division of WCM Industries, Inc.