Specification
When ordering, specify model , inlet and wall thickness.
©2013 WOODFORD Mfg. 1004
SPECIFICATIONS:
• Manufactured under one or more of the following
patents: 3,208,715; 3,278,201; 5,590,679; 5,632,303;
6,142,172; 6,532,986 and patents pending
• ASSE 1019 - Type C Listed
• CSA, cUPC Approved
• Not intended for continuous use
FEATURES:
• Patented resetting pressure relief valve prevents the
faucet tube from bursting in freezing conditions
even if a hose is unintentionally left on.
• 3/4” male hose thread nozzle
• Stainless steel seat - eliminates wire draw
• EPDM packing to prevent leaking
• Full circle operating threads on valve body and retainer
• No-lead solder
• Standard “O” size seat washer
• Oval, powder-coated, die cast aluminum handle
• Optional Tee Key available (extra charge)
• Adjustable polycarbonate wall ange
• MAX PRESSURE - 125 p.s.i.
• MAX TEMPERATURE - 120° F
Freezeless
Anti-Siphon
Wall Faucet
Model 19
This unit offers anti-siphon and non-rupture protection.
15/16
15/16
1 3/8
1 1/16
1 1/4
15/16
15/16
1 3/8
1 1/16
1 1/8
W3=1 1/8
PX, PX3=
1 1/2
W=
15/16
1 1/4
1 3/4
R, W3=
Inlet Descriptions
C Inlet
COMBINATION
Copper Sweat Fitting
1/2” K, L or M Inside
3/4” M Only Outside
CP Inlet
COMBINATION
1/2” Male Pipe Thread
1/2” Female Sweat
CP3 Inlet
COMBINATION
3/4” Male Pipe Thread
3/4” Female Sweat
P Inlet
COMBINATION
1/2” Female Pipe Thread
3/4” Male Pipe Thread
PX Inlet
1/2” PEX Tube Fitting
PX3 Inlet
3/4” PEX Tube Fitting
W Inlet
1/2” Wirsbo
®
Tube Fitting
W3 Inlet
3/4” Wirsbo
®
Tube Fitting
R Inlet
1/2” Rehau
®
Tube Fitting
CM Inlet
COMBINATION
1/2” Compression Fitting
1/2” Copper Sweat Fitting
R
R
U
P
C
R
C
Rev. 02/13 Form No. 19.108
For Installation / Troubleshooting Instructions go to
www.woodfordmfg.com or call 1-800-621-6032
INSTALLATION REQUIREMENTS:
• The faucet length used is to be comparable to what
would be used with standard freezeless faucets.
• The inlet connection must be located in a heated
area.
• The gap between the house and faucet must be
sealed to prevent air leaks.
• The faucet must be installed with a slight downward
pitch toward the nozzle.
• Adequate insulation is required around the faucet,
wall board and sill plate.
The freezeless Model 19 is intended for irrigation purposes
and designed for year-round residential regardless of
outside temperature. This product contains an integral
backow protection device which protects up to 125 psi of
backpressure and therefore does not require an add-on
vacuum breaker.