Figure 4.1 Chimney & Termination Cap Cleaning
C. Grate
Frequency: Aftereachashremoval
By: Homeowner
Inspectgratefor:
• Warpingorsagging1-1/2in.(38mm)ormore
• Brokenwelds
• Burn-throughofgratebars
Forsafeoperation,replaceonlywiththeapprovedgrate
fromHearth&HomesTechnologies.
D. Glass Cleaning
Frequency: Asnecessary
By: Homeowner
Tools Needed:Vinegarorglasscleaner,softtowel
• Cleanglasswithanon-abrasiveglasscleaner.Usea
dampclothdippedinwoodashesoracommercially
availableovencleaner. Remove any ovencleaner
residuewithaglasscleanerorsoapandwater.
F. Refractory
Frequency: Aftereachashremoval
By: Homeowner
• Inspect condition of refractory. Replace if crumbly
orotherwisedeteriorated,orifcracksexceed1/4in.
(6mm).
E. Ash Removal
Frequency: Asnecessary
By: Homeowner
Tools Needed:Coveredmetalcontainer,metal
shovel,replacebroom
WARNING! Risk of Fire! DO NOT remove ashes until
thereisoutandthereplaceiscold.
• Ashesshouldbeplacedinmetalcontainerwithtight
ttinglid.
• The closed container of ashes should be placed
on a noncombustible oor or on the ground, well
awayfromallcombustiblematerials,pendingnal
disposal.
• If the ashes are disposed of by burial in soil or
otherwiselocallydispersed,theyshouldberetained
in the closed container until all cinders have
thoroughlycooled.
Heatilator • A36/42C, A36/42CH Owners Manual • 4017-263 • Rev D • 05/01/14
Chimney
Remove 4 screws
and lift top pan off.
Cap
Slip
Section
ST375
Square
Termination Cap
Cap
Remove screws,
lift top cover.
Top Cover
TR344/TR342
Round
Termination Cap
Chase
Cap
1. Remove the 4 screws.
2. Remove the screen.
3. Remove the baffle.
TS345/TS345P
Square
Termination Caps
TCT375
Terra Cotta
Termination Cap
Remove 2 screws from
the front and back and
lift the top off.
Remove 8 screws
and lift top.
DTO/DTS Series
Termination Cap
Screw
Top
Top