User's Manual

87
Press the Exit Button [oval 17] to Exit Menu to test the learned codes.
Once the appropriate code(s) have been learned and tested, return to the REMOTE CONTROL
SETUP 1 screen to configure the next source’s IR codes. Repeat until all sources are setup for IR
control.
ON-OFF COMM (On-Off Command)
On-Off Command has three options.
SPF: This setting tells the AVR21EN to look at a specific source’s SPF FLAG-IN Jack [circle 39]
on the AVR Rear Panel, to determine ON/OFF Status. This allows the AVR to know when to, or
not to, send power commands to a source component when the AVR is turning on or off. It will
also have the AVR appropriately send power commands to turn a source component ON, when
that source is selected, if it had for some reason turned off.
NOTE: The SPF Jacks [circle 39] are 12VDC inputs that can be used with the Audioaccess SPF
Source Power Flag sensor, or other sensing devices, that output 12VDC when the device being
sensed is ON and 0VDC when the device is OFF.
SEND: If SEND is selected, the AVR will always send a power command to a source component
when the AVR is turned on and again when the AVR is turned off.
DON’T SEND: When DON’T SEND is selected the AVR will never issue power commands to a
source component. The device will need to be turned on and off manually or with some other
method.
To configure SPF, press the Menu Button [oval 44] to bring the MAIN MENU to the screen.
Press the / Navigation Button [oval 16] so that the cursor is pointed to the REMOTE
CONTROL SETUP line. Press the Set Button [oval 18]. The REMOTE CNTL SETUP 1 screen will
appear. Press the / Navigation Button [oval 16] so that the cursor is pointed to the source
to be configured. (For example Disc 1 will be used.) Press the Set Button [oval 18]. The DISC 1
CONTROL SETUP screen will appear. Press the / Navigation Button [oval 16] so that the
cursor is pointed to the ON-OFF COMM line. Press the / Navigation Button [oval 16] to
select SPF if a SPF or other 12V sensor is being used to track a source’s ON/OFF status.
To test, turn both the source and AVR OFF. Turn on the AVR. The source component should turn
on. Turn the AVR OFF. The source component should turn OFF.
HOME THEATER MASTER CONTROL
The AVR21ENR1 remote ON/OFF buttons have two selectable modes when used after pressing
the TV Button. These modes are enabled/disabled in the remote menu under HT MASTER
ON/OFF. (HT is an abbreviation for Home Theater.) See: Programming the AVR21ENR1
Remote Control/HT Master for additional information.
HT MASTER ON/OFF DISABLED: In this mode, after pressing the remote TV Button [oval 6],
the remote ON/OFF Buttons [ovals 1, 2] will turn the Main Room Video Display ON or OFF. All
other buttons will send TV control functions as configured. (Volume up/down, numeric commands,
etc.) In this mode, the TV commands are configured in the remote and are sent from the remote
directly to the TV. This mode does not require any configuration in this setup so if this is how you
are going to control your Main Room components, you may skip this section.
HT MASTER ON/OFF ENABLED: In this mode, after pressing the remote TV Button [oval 6],
the remote ON Button [oval 2] can send IR commands, via the Control Out ALL Jack [circle
35], to turn on the Main Room video display, control the lights and drop a screen or raise a lift. A
press of the remote OFF Button [oval 1] would reverse the process. The IR commands are
configured in the REMOTE CNTL SETUP 2 menu. NOTE: To configure IR commands for HT