User's Manual

WSP-R341 Rev. 1.0
http://www.woosim.com
18
[Example] The defaults of the printer are :
USB / Density Low / Mark No Use / Sensor High / PWDN 5 min slp
If a user wants to modify the defaults with
Bluetooth / Density High / Mark Use / Sensor Low / PWDN No Use
Press FEED & POWER Button during the Error Lamp flickers 5 times.
You will see the Power Lamp and the Error Lamp flickers once.
Press the POWER Button twice and the Error Lamp flickers 3 times.
And then, interface mode has set to Bluetooth mode.
When you press FEED Button once again, Power Lamp flickers 2 times
and Error Lamp flickers once.
Press POWER Button twice, Error Lamp flickers 3 times.
And then the density has set to Density high.
When you press FEED Button once again, Power Lamp flickers 3 times
and Error Lamp flickers once.
Press POWER Button once, Error Lamp flickers twice.
And then the mark has set to Mark use.
When you press FEED Button once again, Power Lamp flickers 4 times
and Error Lamp flickers 4 times.
Press POWER Button once, Error Lamp flickers once.
And then the sensor has set to Sensor Low.
When you press FEED Button once again, Power Lamp flickers 5 times
and Error Lamp flickers 6 times.
Press POWER Button 6 times, Error Lamp flickers once
And then the power down has set to Power down no use.
If all the mode have set, press the POWER Button and the FEED Button
at the same time. After then release the buttons at the same time.
Bluetooth / Density High / Mark Use / Sensor Low / PWDN No Use