POWER button : use for changing OPTION status. (Error Lamp)
FEED button : use for changing MODE status. (Power Lamp)
[Example] The defaults of the printer are :
RS-232C / 9600 bps / 8 data bit / No parity / 1 stop bit / Density low
/ Mark use / Sensor low / Power down 5 minute
If a user wants to modify the defaults with
Bluetooth / 57600 bps / 7 data bit / Odd parity / 2 stop bit / Density high
/ Mark no use / Sensor medium1 / Power down no use
Press FEED & POWER Button during the Error Lamp flickers 5 times.
You will see the Power Lamp and the Error Lamp flickers once.
Press the POWER Button twice and the Error Lamp flickers 3 times.
And then, interface mode has set to Bluetooth mode.
When you press FEED button once again, Power Lamp flickers twice and
the Error Lamp flickers once.
Press POWER Button 3 times, Error Lamp flickers 4 times.
And then, baudrate has set to 57,600 bps.
When you press FEED button once again, Power Lamp flickers 3 times
and the Error Lamp flickers twice.
Press POWER Button once, Error Lamp flickers once.
And then Data Bit has set to 7 data bit.
When you press FEED Button once again, Power Lamp flickers 4 times
and the Error Lamp flickers once.
Press POWER Button once, Error Lamp flickers twice.
And then the Parity bit has set to Odd parity bit.