INSTALLATION
COMMISSIONING
SAFETY:
All relevant safety precautions must be undertaken.
Protective clothing, footwear, gloves and safety
goggles must be worn as appropriate.
PIPEWORK CONNECTIONS:
Flow/open vent 1” BSP 12/18, 18/25.
1
1
/
4
” BSP 25/32.
Primary drain/cold feed
3
/
4
” Ø BSP.
Return 22mm Ø copper 12/18, 18/25.
28mm Ø copper on 25/32 model.
Flue outlet 80/125mm Ø.
Condensate outlet 21.5mm Ø.
NOTE: For servicing purposes, keep the
condensate and pressure relief discharge
pipes away from components and pipework
connections.
CAUTION: Ensure there are no pipes,
electric cables, damp proof courses or
other ha
zards before drilling.
PIPEWORK & FLUE POSITIONS
PIPEWORK & FLUE POSITIONS
I
NSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY EXTERNAL 12/18-18/25-25/32
8 716 112 700a (02.07)
17
C
ondensate
Flue
Ser
vices
P
RV
Fire valve capillar
y
& drain access
Flue
Ser
vices
Condensate
PRV
Oil
Flue
Ser
vices
C
ondens
ate
Oil
PRV
LEFT HAND SIDE
RIGHT HAND SIDE
REAR
Fire valve capillary
& drain access