INSTALLATION
G
D
A
B
C
E
1
4 Align burner combustion head into boiler
collar.
4 Locate the burner retainer (A) over the
threaded lug on the collar (B), push the
burner firmly onto the flange and secure in
place with the retaining nut (C). Tighten
sufficiently but do not overtighten.
4 Check that the burner is seated correctly
on its mounting flange and that the oil
pipe/s are not trapped in front of or
underneath the burner.
4 Refit the deflector plate (D) and secure
with screws (E). Ensure that the flexible oil
pipe/s are not positioned between the
deflector plate and the combustion
chamber door.
4 Attach air duct pipe and tighten clip (F) to
secure to the burner air intake.
2
4 Plug burner lead (G) into control box (H).
1
F
G
H