Instruction manual

A
C
DD
B
STARTING THE APPLIANCE
On 25/32 Appliances:
To achieve the mimimum output of 25kW from the
25/32 RDB 2.2 it is necessary to remove the air
guide (D) from the burner. For any other required
output the air guide must remain in place.
4Disassemble the burner, removing the red
plasic cover, flexible air hose and air intake
manifold (A).
4Remove the fan housing (B) by undoing the
four securing screws.
4Remove the two screws (C) securing the
plastic air guide.
4Remove air guide (D) and reassemble the
burner in reverse order.
STARTING THE APPLIANCE
I
N
S
T
ALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY EXTERNAL 12/18-18/25-25/32
8 716 112 700a (02.07)
33
COMMISSIONING