OPERATING THE APPLIANCE
FAULT CONDITIONS:
The Boiler mode and Lockout lights can indicate
some basic fault conditions.
1 Accessing Controls:
! Undo the screws on the bottom of the
front panel using the tool provided. The
panel can now be removed.
2 Normal operation:
Boiler mode light ON
The appliance is in boiler mode, with a demand
for heat from the controls.
3 Both lights on:
Boiler not firing
! Check the level in the oil tank.
! Press the Reset button (A). The boiler
should fire.
! If there is no response, wait 2 minutes and
press the Reset Button (A) again.
! If Lockout light stays on, do not attempt
further resets. Contact your Service
Engineer for advice.
4 Boiler mode light on, lockout light off:
Boiler not on -
No heating/hot water
! Press Reset Button (B), press Reset Button
(C) both are below the fascia.
! If the boiler remains off, contact your Service
Engineer for advice.
! If this fault re-occurs contact your Installer or
Service Engineer.
5 Both lights off:
Boiler not on -
No heating/hot water
! Ensure there is power supply to the boiler.
! Check the programmer is set to ON and
thermostat is calling for heat.
! Ensure that the Service switch is in Boiler
mode.
! If there is power supply to the boiler contact
your service engineer for advice.
2 NORMAL OPERATION:
3 BOTH LIGHTS ON:
4 BOILER MODE LIGHT ON LOCKOUT LIGHT OFF:
5 BOTH LIGHTS OFF
1 ACCESSING CONTROLS:
OPERATING THE
APPLIANCE
GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM 12/18 - 18/25 - 25/32