Instruction manual

BOILER LOCATION &
CLEARANCES
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY EXTERNAL &
EXTERNAL SYSTEM 12/18-18/25-25/32
8 716 115 667a (05.2009)
15
PRE -
INSTALLATION
BOILER LOCATION &
CLEARANCES
WARNING:
This appliance should not be installed where
there is a potential for excessive ground
water coverage.
This boiler is only suitable for installing
externally at a suitable location onto a fixed
permanent rigid surface capable of
supporting the boiler weight.
There must be a sufficient hard standing
around the appliance to allow for servicing.
The boiler must be installed on a flat level
surface to ensure that condensate does not
enter the primary heat exchanger.
Tarmac and wood hardstandings are not
recommended.
CLEARANCES: Min service & flue clearances
Above 600m
Front 600m
RH/LH clearance flue outlet on opposite side: 10mm
RH clearance flue outlet on rear: 45mm
LH clearance flue outlet on rear: 85mm
Rear clearance flue outlet on side: 50mm**
Rear clearance flue outlet on rear: 2500mm*
It is strongly recommended that the flue
terminal faces away from walls to reduce
the possibility of wetting occuring.
600mm
2500mm
600mm
BASE
FRONT
FRONT
2500mm
*
50mm**
45mm85mm
600mm
10mm
600mm
2500mm
FRONT
FRONT
2500mm
10mm
600mm
Plan
view
Plan
view
Plan
view
600mm min
50mm**