Instruction manual

BOILER INSTALLATION
Note: The cabinet is not load bearing it
only provides weather protection for the
boiler inside.
1Mark position of the 100mm services
duct on the exterior wall and make a hole
through.
2Remove the screws securing the base
panel to the transit pallet and lift the boiler
off the pallet and into its installation
position taking care not to scrape the
base panel across the hard standing. Do
not attempt to lift and position the
boiler on your own. Do not use the
copper pipes to move the boiler.
Fasten the base to the hard standing
using the holes provided. Care should be
taken to ensure that the base is level.
3Remove the key for the door fasteners
from the literature pack.
Undo the screws at the bottom of
the front panel (using the key provided)
and remove the screws from the rear
panel pulling both panels down and out
to remove. Store safely away from the
installation point.
4Remove the screws from the top panel
and lift up to remove, store safely away
from the installation point. Remove the
screw tool from the installation pack.
5aLoosen the flexable air duct clamp (A)
and remove the air duct from the burner.
5bDepress the locking ears to unplug the
burner lead (B) from the control box (C).
5cUndo the two screws securing the
deflector plate (D) and remove the plate.
5dUndo and remove the retainer (E)
on top of the burner. The burner can now
be removed from the heat exchanger.
Store the burner and retainer nut safely
away from the boiler.
Measure the 100mm Ø services duct
to give at least 10mm inside the casing
and to finish flush with the interior wall
surface, cut to size and fit the duct. Fit
the 100mm sealing ring where the duct
enters the casing and seal the joint to
the exterior wall and inside the cabinet
with a suitable sealant.
BOILER INSTALLATION
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY EXTERNAL &
EXTERNAL SYSTEM 12/18-18/25-25/32
8 716 115 667a (05.2009)
22
INSTALLATION
WARNING: THIS APPLIANCE IS SERVICED AND REPAIRED EXTERNALLY.
EXTERNAL EQUIPMENT OPERATED AT 230V SHOULD NOT BE INSTALLED, SERVICED OR
REPAIRED UNDER ADVERSE WEATHER CONDITIONS.
THIS APPLIANCE IS INSTALLED AND SERVICED EXTERNALLY TO THE PROPERTY, BUT
THE ENGINEER MUST HAVE ACCESS TO THE INSIDE OF THE PROPERTY WHEN
INSTALLING OR SERVICING THE APPLIANCE.
2
3
4
4
D
5a
A
5b
B
C
5c
D
5d
E
x4
3
CAMRAY EXTERNAL SYSTEM SHOWN