Instruction manual
REFITTING COMPONENTS
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY EXTERNAL &
EXTERNAL SYSTEM 12/18-18/25-25/32
8 716 115 667a (05.2009)
28
INSTALLATION
REFITTING COMPONENTS
D
A
B
C
E
1 Align burner combustion head into boiler
collar.
Locate the combustion head into the
combustion chamber door, push the burner
firmly onto the door and secure with
retainer (A).
Check that the burner is seated correctly
on its mounting flange and that the oil
hose/s are not trapped in front of or
underneath the burner.
Refit the deflector plate (B) and secure
with screws (C). Ensure that the flexible oil
hose/s are not positioned between the
deflector plate and the combustion
chamber door.
Attach air duct and tighten clip (D) to
secure to the burner air intake.
2 Plug burner lead (E) into control box (F).
1
F
2
E
CAMRAY EXTERNAL REGULAR SHOWN