Technical and Specification Information Greenstar Plus Hybrid System Greenstar Plus Hybrid System NEW 1
Worcester and you, making a difference 2 As part of the Bosch Group, Worcester an experienced award winning technical products are designed and manufactured to services team which is able to provide provide customers with the highest levels of comprehensive support and advice quality and reliability which are synonymous from designing system layouts through with the Bosch name throughout the world. to installation.
The reception and main entrance at our Worcester headquarters Contents Page The Greenstar Plus Hybrid System 4-5 Features and benefits of the Greenstar Plus Hybrid System 6 “At Worcester we recognise the vital role you Principles of operation 7 play in the specification and installation of System layouts 8-9 energy efficient appliances in homes across the UK.
The Greenstar Plus Hybrid System As part of the Bosch Group, Worcester is committed About the Greenstar Plus Hybrid System to innovation and environmental protection. Product The new Greenstar Plus Hybrid System, that works in development is prioritised in the interests of people’s conjunction with selected Greenstar EMS gas-fired or LPG safety, the economical use of resources and condensing boilers, consists of a 5kW external heat pump environmental sustainability. and an indoor Hybrid manager.
System components Outside temperature sensor FW200 controller Greenstar Plus Hybrid external heat pump Greenstar gas-fired condensing boiler Greenstar Plus Hybrid Manager How does the Greenstar Plus Hybrid System work? The FW200 strategy consists of the following: The Greenstar Plus Hybrid System aims to reduce running • Strategy 1: Cost optimised • Strategy 2: CO2 optimised • Strategy 3: Changeover temperature • Strategy 4: CO2: cost mix. costs and increase CO2 savings.
Features and benefits of the Greenstar Plus Hybrid System Greenstar Plus Hybrid Manager External heat pump Homeowner benefits Installer benefits • Future proof – fulfilment of proposed future legislation • Simple to install and maintain – as little as 4 new • • and possible future subsidies to be gained components needed to upgrade to a renewable system Easy integration of renewable energy – new or existing (external heat pump, Hybrid manager, 50l buffer EMS boiler can quickly and easily be u
Principles of operating the Greenstar Plus Hybrid Manager ➊ Data is inputted into the FW200 controller • Calculation of system flow set temperature • The appropriate strategy is chosen – Strategy 1: Cost optimised ➌ Boiler: (the higher temperature heating option) • Supports central heating up to the calculated flow set temperature for the system or supports all DHW demand. Alternatively it can remain turned off.
Examples of system layouts system boiler with serial buffer tank, bypass valve and unmixed heating circuit The Greenstar Plus Hybrid has been developed to allow installers flexibility with a range of heating systems. The diagrams below illustrate a few examples of this. Internal diverter valve required in the boiler.
system boiler with serial buffer tank, bypass valve, unmixed heating circuit and independently controlled mixed heating circuit Greenstar Plus Hybrid with system boiler, DHW cylinder, serial buffer tank, bypass valve, unmixed heating circuit and independently controlled mixed heating circuit DHW cylinder Greenstar EMS condensing boiler FW200 Programming unit TRV TRV Double pole fuse spur Outside temperature sensor Flow Return A A A A No 4 Greenstar Plus Hybrid External Unit 50l serial buffer
Greenstar Plus Hybrid External Unit Fan Service cover, refrigerant pipes and electrical connections Protective grill Technical data Greenstar Plus Hybrid External Unit 7 716 160 021 Part No. Height 600mm Width 800mm Depth 300mm 42kg Weight – lift 230V, 1PH AC 50Hz Mains power supply Maximum heating output (A2W35)1) 4.61kW/2.78 CoP (A2W35)1) 3.85kW/3.14 CoP Rated heating output (A7W35)1) 4.70kW/4.
Greenstar Plus Hybrid Manager Boiler flow Heating system flow Boiler return Heating system return Liquid refrigerant pipe Isolation valves Hydraulic separator Gaseous refrigerant pipe High efficiency pump Heating water temperature sensor (at the condenser outlet) Condenser Flow switch (hidden) Filter Liquid refrigerant temperature sensor (hidden) Drain valve (hidden) Heating water temperature sensor – at the condenser inlet (hidden) Interface to the external unit Hybrid control manager Technical
Greenstar Plus Hybrid FW200 weather compensation controller LCD display DHW heating advance button Central heating advance button Menu button Info button Mode selector Delete/reset button Return to next menu button Selector dial Symbols 12 Current room temperature Holiday mode Flashing segment: current time (09:30 to 09:45) Burner operation on display for heating circuit 1 Solid segments: Time set for operating mode = Comfort today (1 segment = 15 min) Scroll menu/info text up or increase value
Functional description of the Greenstar Plus Hybrid Manager The Greenstar Plus Hybrid Manager monitors the heat High efficiency pump within the Greenstar Plus pump, the condensing boiler and the FW200 weather Hybrid Manager compensation controller.
Is a Greenstar Plus Hybrid system suitable for the property? It is essential that Hybrid systems are designed to operate However, estimates may be made on the basis of the efficiently in order to meet the building heating needs and existing energy consumption of the space to be heated. the expectations of the customer.
Worcester Greenstar boilers compatible with a Greenstar Plus Hybrid system †† Greenstar Si & i System Greenstar CDi Classic Model Greenstar 29CDi Classic Greenstar Highflow CDi Greenstar CDi Compact Boiler type Combi Hot water output Heating outputs 30.9kW 30kW* Part no.
Installing a Greenstar Plus Hybrid system Siting of the external unit External unit casing dimensions and pipework connections Correct siting, assembly and installation of the individual External unit dimensions components are the fundamental requirements for safe and economical operation of the Hybrid system. Installation • The installation surface must be level, firm and of 330mm Foundation 300mm 152mm MCS/MIS 3005 & MCS 020 Planning Standards.
Siting of the indoor unit Indoor unit casing dimensions and pipework connections Rooms where the Greenstar Plus Hybrid Manager or Greenstar Plus Hybrid Manager indoor unit dimensions the refrigerant lines are installed must have an internal 32mm volume of at least 5.7m3, if the room is to be occupied.
Installation and maintenance Refrigerants Designated use The Greenstar Plus Hybrid is filled with R410A refrigerant. The appliance may only be installed in sealed central Only qualified and authorised refrigeration engineers heating systems to BS EN 12828. Any other use is may work on the refrigerant circuit. For all work with considered improper. Any damage that may result is refrigerant, wear suitable safety gloves and goggles. excluded from liability.
The PEF of electricity is generally 2.3, the PEF of oil Windy location and gas is 1.1, the PEF of mixed electric power is 2.6. If the heat pump is sited on a roof or other exposed site, The Coefficient of Performance (CoP) of the heat pump ensure that the air discharge is not directly exposed to is, subject to outside air temperature and water flow strong wind. temperature, between 2 and 5.5.
Installation and maintenance continued Control strategy: cost optimised With the cost-optimised mode, the system control decides The energy:price ratio for electricity and fossil fuel must be on the basis of current energy prices. Rising gas prices adjusted regularly to the actual price ratios. result in longer operation of the heat pump, whilst rising electricity prices result in longer operation of the boiler.
Commissioning considerations – system flushing and care Flushing the system Inhibitor • Fill the system with cold water and check for leaks • Open all drain cocks and drain the system • Close drain cocks and add a suitable flushing agent If the system is exposed to freezing conditions, add a suitable inhibitor or combined inhibitor/anti-freeze in accordance with the manufacturer's guidelines.
Greenstar Plus Hybrid system components Greenstar Plus Hybrid package Worcester Part No. 7 716 162 025 Greenstar Plus Hybrid system accessories 22 Trace heating cable 15mm bypass valve Remote control for service Wall mounting frame 80kg Worcester Part No. 7 716 161 067 Worcester Part No. 7 716 161 058 Worcester Part No. 7 716 161 051 Worcester Part No. 7 716 161 064 Anti-vibration mounts External unit drain pan External unit drain kit Floor mounting kit Worcester Part No.
The very best training programmes from Worcester Worcester has always placed great emphasis on technical Mobile training support and training for installers and service engineers. To complement our training venues across the country, Advances in heating technology, including the increasing use we can also bring training to you. of renewables, make the need for training greater than ever.
Heat pump product courses All academies allow customers to gain hands-on experience with our entire range of renewable products and inform installers about the true benefits of installing heat pumps and underfloor heating. The introduction to heat pumps course is designed for installers and heating engineers who have no experience in installing heat pumps. The various one day heat pump courses are designed for those with more practical experience in heat pump technology.
Additional product and industry training courses The diversity of products in today’s heating industry gives you the opportunity to expand your expertise, whilst offering more choice to your customers. Worcester provides comprehensive training from all its academies on its entire range of technologies. We are here to provide you with training and assistance for all areas of your business, not just product training.
A complete after-sales service As part of the worldwide Bosch Group, Worcester strives to maintain the highest possible standards of after-sales care.
Notes 27
Useful numbers Customer Service Sales Engineer Appointments Tel: 01905 752640 Email: appointment.worcester@uk.bosch.com Fax: 01905 456445 or telephone 0844 892 3000 Spare Parts Enquiries Tel: 01905 752576 Email: service.mailbox@uk.bosch.com Fax: 01905 754620 or telephone 0844 892 3000 Technical Helpline (Pre & Post Sales) Guarantee Registration Tel: 0844 892 3366 To register your Worcester guarantee, Fax: 01905 752741 please visit our website or technical.enquiries@uk.bosch.