Technical data
10
Greenstar Plus Hybrid External Unit
Technical data
Greenstar Plus Hybrid External Unit
Part No.
7 716 160 021
Height
600mm
Width
800mm
Depth
300mm
Weight – lift
42kg
Mains power supply
230V, 1PH AC 50Hz
Maximum heating output (A2W35)
1)
4.61kW/2.78 CoP
Rated heating output (A2W35)
1)
3.85kW/3.14 CoP
Rated heating output (A7W35)
1)
4.70kW/4.42 CoP
Maximum heating output (A7W35)
1)
6.08kW/4.11 CoP
Rated heating output (A7W35)
1)
2.99kW/2.31 CoP
Maximum current
13A
Recommended MCB/fuse rating
16A MCB type D
IP rating
IP24
Refrigerant filling
2.5kg
Air flow rate
35m
3
/min
Sound pressure level to EN 12102
2)
46dB(A)
Outside air temperature operating range
-9 to +21ºC
Water flow temperature operating range
+20 to +50ºC
Maximum line length/height difference
30m/30m
Pipework for liquid refrigerant external diameter
¼"
Pipework for gaseous refrigerant external diameter
½"
1) Reference conditions: to EN 14511-2:2007
2) Measured at a horizontal distance of 1m and a height of 1.5m taken from the appliance bottom
Service cover,
refrigerant pipes
and electrical
connections
Fan
Protective grill