Technical data
28
Option 5: Extension flue upwards and horizontal
Components
Part No. 100mm
7 716 191 155 7 716 191 083 7 716 191 084 7 716 191 164
Part No. 125mm
7 716 191 157 7 719 003 666 7 719 003 664 7 716 191 165
Maximum lengths (mm) & no. of components required
Greenstar Highfl ow CDi series
100mm 2,500 1 up to 2 1 1
125mm 11,000 1 up to 10 1 1
Option 6: Extension flue upwards and horizontal
using a second 90º bend
Components
Part No. 100mm
7 716 191 155 7 716 191 083 7 716 191 084 7 716 191 164
Part No. 125mm
7 716 191 157 7 719 003 666 7 719 003 664 7 716 191 165
Maximum lengths (mm) & no. of components required
Greenstar Highfl ow CDi series
100mm 1,000 1 up to 2 2 1
125mm 9,000 1 up to 8 2 1
Min.
120mm
Option 7: Extension flue upwards and horizontal
using a third 90º bend
Components
Part No. 100mm
7 716 191 155 7 716 191 083 7 716 191 084 7 716 191 164
Part No. 125mm
7 716 191 157 7 719 003 666 7 719 003 664 7 716 191 165
Maximum lengths (mm) & no. of components required
Greenstar Highfl ow CDi series
100mm N/A N/A N/A N/A N/A
125mm 7,000 1 up to 6 3 1
Min.
120mm
Option 8: Side flue extension using two 45º bends
Components
Part No. 100mm
7 716 191 155 7 716 191 083 7 716 191 085
Part No. 125mm
7 716 191 157 7 719 003 666 7 719 003 665
Maximum lengths (mm) & no. of components required
Greenstar Highfl ow CDi series
100mm 2,500 1 up to 2 2
125mm 11,000 1 up to 10 2
Note: The short flue extension (100mm dia.) may be used as
an alternative to the standard extension as required up to
the maximum flue lengths stated (Part No. 7 716 191 133).
For high level horizontal flue discharges (options 5,
6 and 7) the flue adaptor (part number 8 718 682 324 0)
may be required.
45º bend 90º bend
Greenstar Highfl ow CDi
60/100mm fl ues
750mm 1,500mm
Greenstar Highfl ow CDi
80/125mm fl ues
750mm 1,500mm
Note: The maximum fl ue length must be reduced by the
following amounts for each bend used.
Min.
120mm