Technical data

30
Option 1: Vertical balanced flue assembly
Components
Part No. 100mm
7 716 191 156 7 716 191 083
Part No. 125mm
7 716 191 158 7 719 003 666
Maximum lengths (mm) & no. of components required
Greenstar Highfl ow CDi series
100mm 6,400 1 up to 6
125mm 15,000 1 up to 14
300mm
500mm
Pitched
roof
Flat roof
Option 2: Vertical balanced flue using two 45º bends
Components
Part No. 100mm
7 716 191 156 7 716 191 083 7 716 191 085
Part No. 125mm
7 716 191 158 7 719 003 666 7 719 003 665
Maximum lengths (mm) & no. of components required
Greenstar Highfl ow CDi series
100mm 4,900 1 up to 5 2
125mm 13,000 1 up to 12 2
Min.
120mm
Option 3: Vertical balanced flue using two 90º bends
Components
Part No. 100mm
7 716 191 156 7 716 191 083 7 716 191 084
Part No. 125mm
7 716 191 158 7 719 003 666 7 719 003 664
Maximum lengths (mm) & no. of components required
Greenstar Highfl ow CDi series
100mm 3,400 1 up to 3 2
125mm 11,000 1 up to 10 2
Min.
120mm
Note: The short flue extension (100mm dia.) may be used
as an alternative to the standard extension as required up to
the maximum flue lengths stated (Part No. 7 716 191 133).
45º bend 90º bend
Greenstar Highfl ow CDi
60/100mm fl ues
750mm 1,500mm
Greenstar Highfl ow CDi
80/125mm fl ues
750mm 1,500mm
Note: The maximum fl ue length must be reduced by the
following amounts for each bend used.