Technical data

SERVICING AND SPARES
6 720 648 547 (2012/06) 33
Fig. 49 Fitting bottom panel
6 SERVICING AND SPARES
6.1 INSPECTION AND SPARES
To ensure the continued efficient operation of the appliance it must be
checked at regular intervals.
The frequency of servicing will depend upon the particular installation
conditions and usage. However, an annual service is recommended.
The extent of the service required by the appliance is determined by
the operating condition of the appliance when tested by fully
qualified engineers.
INSPECTION
1. Check that the terminal and the terminal guard, if fitted, are clear and
undamaged.
2. If the appliance is in a compartment or cupboard check that the
specified service space around the appliance is clear.
3. Check all the joints and connections in the system and remake any
that show signs of leakage. Refill and re-pressurise if applicable as
described in Commissioning.
Operate the appliance and take note of any irregularities. Call up the
last fault stored by the Bosch Heatronic, Service Function .0. Refer to
Fault Finding for rectification procedures.
CAUTION: Isolate the mains gas supply before starting
any work and observe all relevant safety precautions.
NOTICE: After replacement of any components always
check for gas tightness where relevant and carry out
functional checks as described in commissioning. Any
O-rings or gaskets that are disturbed during servicing
must be replaced.
C
D
6720647361-26.3Wo
NOTICE: Any service work must be carried out by a
competent registered engineer such as British Gas or
Gas Safe.