CONDENSATE CONNECTION:
Never terminate or discharge into any open
source, including; sink, bath, shower, bidet,
toilet etc.
Note: any external condensate pipework
should be protected with weather resistant
insulation to help prevent freezing.
Ensure that the condensate drain is 22mm
diameter plastic pipe. It must fall at least
50mm per metre towards the outlet.
An adapter in 22mm pipe is contained in the
fitting pack (A) along with sealing washer (B).
CONDENSATE CONNECTION
A
B
CONDENSATE CONNECTION
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 12i System/24i System
8 716 107 375b (11/05)
26
INSTALLATION
IMPORTANT: IF FITTING OPTIONAL
INTEGRAL DIVERTER VALVE
Now fit the diverter valve. For installa-
tion refer to FITTING THE DIVERTER
VALVE in the ADDITIONAL INFORMATION
section at the back of the book. You must
then disregard the following 3 pages con-
cerning ELECTRICAL and PRE-COMMIS-
SIONING CHECKS and refer to the cor-
rect versions that follow FITTING THE
DIVERTER VALVE in the ADDITIONAL
INFORMATION section at the back of this
book.