Instruction manual

Flat at back
FLUE INSTALLATION
ASSEMBLING THE FLUE
4 Assemble elbow to boiler using the three
screws (see below).
NOTE: Screws are in boiler not in flue kit.
FITTING THE ELBOW:
Flue elbow should push directly down and
not be twisted into correct position.
Remove the 3 inner flue tube retaining
screws. The inner tube will be held in place
in the appliance.
Fit turret onto appliance and retain with the
three removed screws.
NOTE: The clamping plate flat should be at
the rear of the appliance.
ADDITIONAL NOTES AND REMINDERS:
Ensure that all cut lengths are square and
free from burrs.
The flue, when assembled, is fully sealed and
components are pushed home.
The flue is set at an angle of 3° or 52mm per
1m length.
This screw should
be fitted last for
easier installation
when rear exit
This screw should
be fitted last for
easier installation
Apply silicone
grease to seal
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 12i/24i System
8 716 115 167b (03/2009)
27
FLUE INSTALLATION
INSTALLATION