Technical data

6 720 611 137 GB (03.02)
10
Installation regulations
Condensate analysis, mg/l
Flue system
Elbow - 90 ° Equivalent length 2 m
Bend - 45 ° Equivalent length 1m
Gas supply
2 Installation regulations
Gas Safety (Installation & Use) Regulations: All gas
appliances must be installed by a competent person.
Failure to install correctly could lead to prosecution.
The manufacturers notes must not be taken, in any way,
as overriding statutory obligations.
The appliance must be installed in accordance with the
current IEE Wiring Regulations, local Building Regula-
tions, Building Standards (Scotland) (Consolidation),
bye-laws of the local Water Company, Health and
Safety Document 635 (Electricity at Work Regulations
1989) and any other local requirements.
Product Liability regulations indicate that, in certain cir-
cumstances, the installer can be held responsible, not
only for mistakes on his part but also for damage result-
ing from the use of faulty materials. We advise the
installer to avoid any risk by using only quality approved
branded fittings.
The relevant British Standards should be followed i.e.
BS 6798: Specification for the installation of gas
fired hot water boilers of rated input not exceeding
60kW
BS 5449: Central Heating for Domestic Premises
BS 5546: Installation of gas hot water supplies for
domestic purposes
BS 5440:1: Flues and ventilation for gas appliances
of rated input not exceeding 70 kW (net): Flues
BS 5440:2: Flues and ventilation for gas appliances
of rated input not exceeding 70 kW (net): Air
Supply
BS 6891: Installation of low pressure gas pipework
installations up to 28mm (R1).
BS 6700: Domestic water supply (when relevant)
BS 7671: Requirements for Electrical Installation.
These instructions must be followed.
Ammonium 1.2 Nickel 0.15
Lead 0.01 Mercury 0.0001
Cadmium 0.001 Sulphate 1
Chromium 0.005 Zinc 0.015
Halogenated
hydrocarbons 0.002
Tin 0.01
Hydrocarbons 0.015 Vanadium 0.001
Copper 0.028 pH-value 4.8
Table 3
HORIZONTAL 100 mm – Standard
Overall Diameter of Duct mm 100
Max.
4 m
Flue Terminal / Duct
Assembly Length mm 600
Extension Duct Length mm 1000
Table 4
VERTICAL 100 mm – Standard
Overall Diameter of Duct mm 100
Max.
6.4 m
(incl.
flue
assem-
bly)
Flue Terminal / Duct
Assembly mm 600
Extension Duct Assembly mm 1000
Table 5
ALTERNATIVE HORIZONTAL 125 mm FLUE
SYSTEM
Overall Diameter of Duct mm 125
Max.
13 m
(inclu-
ding
turret)
Flue Terminal / Duct Assembly mm 1030
Extension Duct Length mm 1000
Table 6
VERTICAL 125 mm FLUE SYSTEM
Overall Diameter of Duct mm 125
Max.
15 m
Flue Terminal / Duct Assembly mm 1360
Extension Duct Length mm 1000
Table 7
Total length of gas supply pipe
(metres)
Pipe diameter
(mm)
369
Gas discharge rate (m
3
/h)
8.7 5.8 4.6 22
18.0 12.0 9.4 28
Table 8