Technical data
7 181 465 346 GB (03.02)
Bosch Heatronic board functions
9
Values that can only be read:
Description Display Reset Value
.1 Heating outlet temperature. 0 - 99˚C -
.2 Sanitary outlet temperature. 0 - 99˚C -
.3 Heat store NTC sensor (ZSB.) 0 - 99˚C
.4 Constant hot water NTC sensor (ZWB.) 0 - 99˚C -
1.2 Order no. for code plug: 8 714 411 XXX 0 - 255 -
1.4 Temperature voltage signal (Terminal 2) from room thermostat
(eg. TRQ 21, TR 100)
5 - 22 VDC -
1.5 Specified CH flow temperature from programmer 0 - 99˚C -
1.6 Outside temperature from TA 211 E or room temperature from
TR 212 E
-20 +30˚C -
1.7 Status TR 2 (0 = Not present 1 = Frost protection 3 = Auto 4 = Day,
Night 5=Error)
0 - 4 -
1.8 Terminal 2 on programmer interface module 0 - 24 VDC -
1.9 Identification code for the external module:
0, 2, 4, 5 = no module connected,
3 = ADM, 6 = TA 211E, 53 = ADM, 56 = TR 212 E).
0 - 8, 53,
56
-
2.9 Instantaneous power. 0 - 99 % -
3.0 Fan speed 0 - 105 -
3.3 Quality of the ionisation signal:
0 = no ionisation,
1 = weak ionisation,
2 = medium ionisation,
3 = high ionisation.
0 - 3 -
3.6 Software version 3 x 2
positions
-
Table 2 First Service Level; Values that can only be read