Technical data

7 181 465 346 GB (03.02)
32
Failure identification procedure
EA and flashing.
No flame ionisations signal
Check Action
B Note the setting of the temperature controls
and .
1. Is the flame present? yes: 6.
no: 2.
2. Is the gas cock open? yes: 3.
no: B Open the gas cock.
B Press , restart the appliance.
EA? 3.
3. Is there air in the supply pipe? yes: B Vent supply pipe.
B Press , restart the appliance.
EA? 4.
no: 4.
4. Did the thermal security of the gas
cock lock out?
yes: B Reset security.
B Press , restart the appliance.
EA? 5.
no: 5.