Technical data
7 181 465 346 GB (03.02)
44
Failure identification procedure
Ignition too harsh, ignition poor
Check Action
B Note the setting of the temperature controls
and .
1.
B Press buttons and simulta-
neously.
B Select service-function 5.1.
Continuous ignition (without gas)
OK?
yes: ↓6.
no: ↓2.
2. Ignition lead connected to ignition
electrodes?
yes: ↓3.
no: B Connect cable to ignition electrodes.
B Press button .
Ignition poor? ↓3.
3. Ignition cable connector engaged in
switchbox?
yes: ↓4.
no: B Power OFF the appliance.
B Engage ignition cable connector in switchbox.
B Turn ON the appliance.
B Press button .
Ignition poor?
B Power OFF the appliance.
↓4.
4. Is the ignition electrical wire dam-
aged?
yes: B Power OFF the appliance.
B Change the ignition electrical wire.
B Turn ON the appliance.
B Press button .
Ignition poor?
B Power OFF the appliance.
↓5.
no: ↓5.
5. Electrode assembly defective?
B Power OFF the appliance.
B Remove electrode assembly.
Electrodes worn out?
yes: B Replace electrode assembly.
B Turn ON the appliance.
B Press , restart the appliance.
Ignition poor? ↓6.
no: B Refit electrode assembly.
B Turn ON the appliance.
B Press , restart the appliance.
Ignition poor? ↓6.