Technical data
6 720 611 445 GB (04.05)
Details of the appliance
5
1.4 Accessories
• Standard horizontal flue kit at 100 mm outside
diameter for flues up to 4 m in length (3.5m for the R
40 HE).
• Flue duct kits for horizontal (125 mm outside
diameter) for flue lengths up to 13m (R 29 HE ) or
10m (R 40 HE) and vertical flue systems for flue
lengths up to 15 m (R 29 HE) or 12 m (R 40 HE). Fit-
ting instructions are sent with these kits.
1.5 Casing dimensions
Fig. 1
13
Manifold assembly
101
Outer case
103
Facia cover
X
Standard Concentric Horizontal Flue System: min. 160 mm
Alternative Concentric Flue System: min. 220 mm
Y
Standard Concentric Horizontal Flue System: 40 mm
Alternative Concentric Flue System: 70 mm
Z
Standard Concentric Horizontal Flue System: 105 mm
Alternative Concentric Flue System: 130 mm
*
For servicing the appliance
Note:
Horizontal flue only: dimension X may need to increase due to
the incline of the flue.
min.
10
min.
10
850
440
395
200
360
873
200
30
6 720 611 441- 01.1O
101
103
35
X
13
Y
120
600
Z
*
*
*
*