Technical data

6 720 611 445 GB (04.05)
10
Details of the appliance
Condensate analysis, mg/l
Flue system
Elbow - 90 ° Equivalent length 2 m
Bend - 45 ° Equivalent length 1m
Gas supply
Ammonium 1.2 Nickel 0.15
Lead 0.01 Mercury 0.0001
Cadmium 0.001 Sulphate 1
Chromium 0.005 Zinc 0.015
Halogenated
hydrocarbons 0.002
Tin 0.01
Hydrocarbons 0.015 Vanadium 0.001
Copper 0.028 pH-value 4.8
Table 3
HORIZONTAL 100 mm – Standard FLUE SYSTEM
Overall Diameter of Duct
mm
100
Max.
R29 4m
R40 3.5m
(including
turret)
Flue Terminal / Duct
Assembly Length
mm
600
Extension Duct Length
mm
1000
Table 4
VERTICAL 100mm FLUE SYSTEM
Overall Diameter of Duct mm 100 Max. (Incl.
terminal)
R29 6.4 m
R40 5.4 m
Flue Terminal / Duct
Assembly Length
mm 1140
Table 5
HORIZONTAL 125 mm FLUE SYSTEM
Overall Diameter of Duct mm 125 Max.
R29 13m
R40 10m
(including
turret)
Flue Terminal / Duct
Assembly Length
mm 1030
Table 6
VERTICAL 125 mm FLUE SYSTEM
Overall Diameter of Duct mm 125 Max. (Incl.
terminal)
R29 15 m
R40 12 m
Flue Terminal / Duct
Assembly Length
mm 1365
Table 7
Total length of gas supply pipe
(metres)
Pipe diameter
(mm)
369
Gas discharge rate (m
3
/h)
8.7 5.8 4.6 22
18.0 12.0 9.4 28
Table 8