Contents 03 04 05 06 09 10 10 11 12 14 14 14 15 17 18 19 20 22 23 25 26 27 27 28 28 28 29 Warranty details Introduction Proper use Safety advice Additional safety advice for lasers Disposal of device Battery instructions List of contens Description of parts / scope of delivery Operation Insert battery Displays Avoiding measurement errors Distance measurement Addition (without M+storage) Addition (with M+storage) Area Area addition in area mode Volume Volume addition in volume mode Temperature display Batte
Introduction Proper use We congratulate you on your new ultrasound distance measurer and are convinced that you will be satisfied with this state-of-the-art device. The device conforms to the relevant safety regulations.
Safety advice Safety advice The electronic multi-measurement device GT-UDM-02 is a class II laser device and conforms with international safety guidelines 21CFR 1040.10, 1040.11 and EN 60825-1:2007 Do not remove the labels from the device. Take environmental influences into consideration! Do not expose the device to rain. Do not use the device in a damp or wet environment. Ensure that your work area is well lit. Do not use the device in locations where there is a risk of fire or explosion, e.g.
Safety advice Safety advice eyes of another person. Do not look at the laser beam with binoculars or a magnifying glass. Use the correct device! The proper use is described in these operating instructions. Warning! The use of attachment devices or accessories other than those recommended in these instructions or carrying out work with this device that is not in accordance with proper use can lead to risk of accidents. Check your device for damage! Do not drop the device.
Safety advice Safety advice Disposal of device Please dispose of this product and battery responsibly at end of life. Do not throw away with household waste. Please contact your retailer or local authority for details of recycling schemes operating in your area. • Avoid contact with skin, eyes and mucous membranes. Upon contact with battery acid, rinse the affected areas with plenty of clear water and immediately call on a doctor. • Remove dead batteries from the device and dispose of them responsibly.
Description of parts / scope of delivery Description of parts / scope of delivery 1. Ultrasound transmitter/receiver 2. Direction-finding laser 3. Double row LCD display The data in the top row show the current measurement result and the data in the bottom row show the memory/calculation result 4. BASE – The distance measurement can be calculated from two points. Pressing the BASE key can set the distance measurement between the baseline and top of the device. 5.
Operation Operation Insert battery Avoiding measurement errors Open the battery compartment cover on the reverse of the device, pull the connector forward slightly and press the battery (9 V block battery, size 6F22) onto the connector. Insert the battery into the compartment and close the compartment cover. Note the following points in order to avoid measurement errors: 1. Measurements through glass are not possible 2. Distance measurement of sound-absorbent items (e.g. curtains) is not possible. 3.
Operation Operation 9. Nearby additional ultrasound devices or high frequency sounds: switch off the source(s) of noise during measurement. 10. With unfavourable measurement conditions: Temperature and humidity influence the precision of measurement – the temperature of the device should agree with the environmental temperature, particularly when measuring larger distances (between 12 m to 16 m/ 40 ft. and 53 ft.
Operation Operation Tips: A. The measured object should have a hard surface and not be blocked by obstacles; B. In order to obtain precise results, select a large, smooth, hard surface; C. If the measured surface is too small, irregular or too soft, chipboard can be used on the surface of the measured object; D. This device can not be used to measure through glass; E. The device should be further than 60 cm away from the measured object during measurement; F.
Operation Operation • Adding memory to last measurement result: Press +/= for at least 2 sec. until a double beeping tone sounds. “M” will disappear from the display. Only the saved value will be shown in the bottom of the display. • The width symbol “W“ in the display flashes and shows the next measurement to be carried out.
Operation Operation Area addition in the area mode: • Keep the MODE button pressed down in order to save the calculated area from the first measurement; at the same time, the “M+” symbol appears on the display. A double beeping tone will sound; • Press the +/= button – the sum of both areas appears in the bottom section of the display; • Repeat the above mentioned steps, in order to further add up the measured area.
Operation Operation • The width symbol “W“ in the display flashes to indicate the next measurement to be carried out. Press the READ button in order to measure the width, the result appears in the upper section of the display. (Step 2); • The height symbol “H“ in the display flashes and indicates the next measurement to be carried out. Press the READ button in order to measure the height, the result appears in the upper section of the display.
Operation Operation • Press the +/= button – the sum of both volumes will appear in the lower section of the display; Battery display Empty battery: Here, the symbol constantly appears in the display in order to remind you to change the battery. • Repeat the above mentioned steps, in order to continue adding the measured volumes. Switching off the device Temperature display Keep the FT/M button pressed for approx. 2 seconds – the temperature appears in the lower section of the display.
Cleaning Technical data The ultrasound distance measurement device is maintenance-free. Clean the device with a dry or slightly damp cloth. Storage Keep the device in a dry and frost-free location. The device must be kept out of reach for children. Disposal of device Please dispose of this product and battery responsibly at end of life. Do not throw away with household waste. Please contact your retailer or local authority for details of recycling schemes operating in your area.
AFTER SALES SUPPORT: Telephone: E-mail: 1800 269 981 support@eurocentra.com.au AFTER SALES SUPPORT: 30 Telephone: E-mail: 1800 269 981 support@eurocentra.com.