Owner`s manual

World Class Catamarans
5-6
RAW WATER SYSTEM
The raw water pump is located in the aft rigging compartment on the port side, and can be
accessed through the hatch located on the vertical wall beneath the livewell. The pump and wir-
ing are mounted on the rigging wall at the back of the compartment. The raw water pump is
connected to the dual purpose livewell pump which brings in water through a strainer located
on the inboard side of the port sponson. The livewell/raw water seacock must be open for the
system to work, however, the livewell pump does not have to be “ON”. Similar to the freshwater
pump, the raw water system in controlled by a pressure switch set at 50 psi. The pump will
cycle on and off as needed to maintain this pressure. Most owners leave the pump “on” through-
out the day, and use the system when necessary. On the 270 SD, the raw water pump feeds the
raw water outlet located on the starboard cockpit wall. To view the layout of the raw water sys-
tem see the drawing on page 15.
PORTABLE HEAD INSTRUCTIONS
PREPARATION
1. On the rear of the toilet, slide the locking lever to the unlocked position and separate the
unit.
2. Open the holding tank valve, located on the bottom half of the head, and fill the reservoir
with the deodorant provided.
3. Complete the preparation by adding enough water to cover the bottom of the tank.
4. Reassemble the unit and fill the freshwater reservoir by removing the cap on the rear
right hand corner of the unit. Replace the cap when finished.
BEFORE USE
1. With the seat cover c losed open and close the holding tank valve located on the front
of the head. This will eliminate any pressure that has built up between uses.
2. Compress the bellows pump located on the rear left hand corner of the unit a few times
to add water to the bowl.
AFTER USE
1. Flush the toilet by pulling the holding tank valve out, and compressing the bellows pump
to rinse the bowl.
2. Push the valve back in completely to ensure an odor tight seal.
EMPTYING
1. Verify the holding tank valve is closed, then separate the units using the locking lever on
the rear of the head.
2. Remove the waste tank from the hold down brackets and carry to any permanent toilet
facility.
3. Rotate the discharge spout as needed, remove the cap, and depress the air relief valve to
empty.
4. Rinse the tank and refill as directed in the preparation steps above.
WINTERIZATION
1. For cold weather use or storage, fill the freshwater reservoir with any non-toxic anti-
freeze.
2. Add a chemical deodorant to the holding tank.
3. Flush the unit a few times, with the anti-freeze in place, to winterize the bellows pump.