5202D Scanner ™ 2D Omni-Directional Bar Code Scanner Worth Data® 5202D 2D Bar Code Scanner USB & Serial Output www.worthdata.
Warning: This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, it may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated ina commercial environment.
Table of Contents Introduction Chapter 1 Installation ..................................................................................................................1-1 Components of LZ520-2D Reader ................................................................................................................................1-1 USB Installation on a PC or Mac ..................................................................................................................................
Introduction Worth Data's LZ520-2D is a versatile bar code reader that can attach to any PC or Mac USB port. It can also be used as an external reader for the Worth Data T7000 series of RF Terminals or T5000 series of TriCoders. The USB keyboard interface provides bar code input data to any host computer program exactly as if the data had been typed at the keyboard, including function and control key support.
Chapter 1 Installation Components of LZ520-2D Reader In the event the shipping box shows damage on arrival, please note the damage on the carrier's receipt log. Open the box and inspect the contents for damage. If there is visible damage, or if the unit fails to work, contact us with the details of the trouble; we will be happy to send you a replacement. The contents of your LZ520-2D reader shipment should include the following: 1. An LZ520-2D reader with either USB or serial cable attached. 2.
Chapter 2 Configuration Configuration of the LZ520-2D Reader The LZ520-2D is configured using the setup bar codes found in Appendix A. Most commands are of the single entry type and only require a single command to enable or disable a feature or function. To change the configuration of a setting start by scanning the “Start Setup” bar code followed by the bar code for the setting(s) you wish to change and then the “End Setup” bar code.
Appendix A 1D Codes: Code Type Enabled by Default Additional Setup Info UPC yes page A-4 EAN yes page A-5 EAN-13 yes page A-5 EAN-8 yes page A-5 Code 39 yes page A-7 Codabar yes page A-8 Code 128 yes page A-10 Code 93 yes page A-11 Code 11 no page A-12 Industrial 2 of 5 yes page A-13 Interleaved 2 of 5 yes page A-13 S-Code yes page A-13 Matrix 2 of 5 no page A-13 Chinese Post Matrix 2 of 5 no page A-13 MSI/Plessey yes page A-14 UK/Plessey yes page A-15 POS
2D codes: Code Type Enabled by Default Additional Setup Info PDF417 yes page A-24 Micro PDF417 yes page A-25 Maxi Code yes page A-26 QR Code yes page A-27 Micro QR yes page A-28 Aztec Code yes page A-29 Aztec Runes no page A-30 Data Matrix (ECC 200) yes page A-31 Data Matrix (ECC 000-140) no page A-31 Codablock F no page A-32 Chinese Sensible Code no page A-33 All Codes no page A-34 Other Options: Item Setup Info Number of Characters page A-35 Composite Codes page
Set to factory default: To set the scanner to factory defaults, scan one of the codes below. Set USB I/F and Reset All Settings to Default Set RS-232 I/F and Reset All Settings to Default Note: The RS-232 I/F setting applies to the LZ520-2D when used as an external scanner attached to portable devices such as the Terminal and TriCoder. Warning: These setup codes are for the LZ520-2D only. Do not use these codes to setup the 2D scanner on a 2D integrated Terminal or TriCoder.
UPC Start Setup End Setup [[ [[ UPC-A Settings: UPC-A, no leading zero, transmit check digit default F! F6 F3 F5 default F8 F: F7 F9 7R 7Q LQ LR UPC-A UPC-A, no leading zero, not transmit check digit leading zero check digit transmission UPC-A, leading zero, transmit check digit UPC-A, leading zero, not transmit check digit UPC-E Settings: UPC-E, no leading zero, transmit check digit UPC-E UPC-E, no leading zero, not transmit check digit leading zero check digit transmission UPC-E, leading zero, t
EAN Start Setup End Setup [[ [[ EAN Settings: not transmit EAN-13 check digit EAN-13 and EAN-8 Check Digit Transmission EAN-13 and EAN-8 ISBN Conversion transmit EAN-13 check digit default not transmit EAN-8 check digit transmit EAN-8 check digit default disable ISBN conversion default JC JB JL default IO IP 5W default JP JQ JR enable ISBN conversion enable ISBN if possible disable ISSN conversion EAN-13 and EAN-8 ISSN Conversion enable ISSN conversion enable ISSN if possible disable ISMN
EAN Supplement Settings: EAN Symbologies EAN no supplement (default enable) EAN with 2-digit supplement EAN with 5-digit supplement Exclusive Enable Disable K5 K6 K7 S5 S6 S7 Y5F Y5G Y5H Exclusive Enable Disable KH KI KJ KV KW KX N/A Exclusive Enable Disable KB KC KD KP KQ KR N/A note: setting any symbology to exclusive will disable all other symbologies EAN-13 Supplement Settings: EAN Symbologies EAN-13 no supplement (default enable) EAN-13 with 2-digit supplement EAN-13 with 5-digit su
Code 39 Start Setup End Setup [[ [[ Code 39 Settings: Code 39 Exclusive Enable Disable Code 39 Enable/Disable (default enable) B3 C3 WC note: setting any symbology to exclusive will disable all other symbologies normal code 39 Full ASCII Conversion default E6 E5 ,L default D2 D1 E9 E: full ASCII code 39 full ASCII code 39 if possible not check CD Code 39 and It Pharmaceutical Check Digit (CD) check CD not transmit CD transmit CD default not transmit start/stop default transmit start/s
Codabar Start Setup End Setup [[ [[ Codabar Settings: Codabar Exclusive Enable Disable Codabar Enable/Disable (default enable) B! C! WD note: setting any symbology to exclusive will disable all other symbologies enable only Codabar normal mode Codabar ABC, CX Conversion default IB I5 I6 I! default I8 I7 I: I9 enable only ABC code enable only CX code enable Codabar / ABC and CX not check CD Codabar Check Digit (CD) check CD not transmit CD transmit CD default not transmit start / stop d
Codabar Settings Continued: minimum data = one character Codabar Minimum Digit Codabar Space Insertion Codabar Inter-Character Gap Check minimum data = three characters minimum data = five characters default disable space insertion default enable space insertion disable inter-character gap check enable inter-character gap check A-9 default ID IC IG IF IE IJ II
Code 128 Start Setup End Setup [[ [[ Code 128 Settings: Codabar Exclusive Enable Disable Code 128 Enable/Disable (default enable) B7 C7 WF note: setting any symbology to exclusive will disable all other symbologies disable GS1-128 Code 128 and GS1-128 (EAN-128) EAN-128 Conversion default enable GS1-128 only enable EAN-128 if possible Code 128 and GS1-128 (EAN-128) Concatenation disable concatenation (FNC2 message append) default enable concatenation (FNC2 message append) A-10 PG KG PH NQ N
Code 93 Start Setup End Setup [[ [[ Code 93 Settings: Symbology Code 93 (default enable) Exclusive Enable Disable B6 C6 WE note: setting any symbology to exclusive will disable all other symbologies Code 93 Check Digit (CD) not transmit CD default transmit CD A-11 E[ EZ
Code 11 Start Setup End Setup [[ [[ Code 11 Settings: Symbology Code 11 (default disable) Exclusive Enable Disable CMC CMD CMB note: setting any symbology to exclusive will disable all other symbologies not check CD check 1 CD Code 11 Check Digit (CD) check 2 CD check auto 1 or 2 CD default not transmit CD default transmit CD A-12 CMG CMH CMI CMJ CMK CML
2 of 5 and S-Code Start Setup End Setup [[ [[ 2 of 5 and S-Code Settings: Symbology Industrial 2 of 5 (default enable) Interleaved 2 of 5 (default enable) S-Code (default enable) Matrix 2 of 5 (default disable) Exclusive Enable Disable K8 K9 SB BC S8 S9 S: CC Y5L Y5M N/A N/A Chinese Post Matrix 2 of 5 (default disable) note: setting any symbology to exclusive will disable all other symbologies KF KT not check CD 2 of 5 and S-Code Check Digit (CD) default check CD not transmit CD transmit CD
MSI / Plessey Start Setup End Setup [[ [[ MSI / Plessey Settings: Symbology MSI / Plessey (default enable) Exclusive Enable Disable B8 C8 WG note: setting any symbology to exclusive will disable all other symbologies not check CD check 1 CD = mod 10 MSI / Plessey Check Digit (CD) default check 2 CD = mod 10/mod 10 check 2 CD = mod 10/mod 11 check 2 CD = mod 11/mod 10 check 2 CD = mod 11/mod 11 not transmit CD MSI / Plessey Check Digit (CD) Transmission transmit CD 1 default transmit CD 1 an
UK / Plessey Start Setup End Setup [[ [[ UK / Plessey Settings: Symbology UK / Plessey (default enable) Exclusive Enable Disable B2 C2 WB note: setting any symbology to exclusive will disable all other symbologies UK / Plessey Check Digit (CD) UK / Plessey Space Insertion UK / Plessey X Conversion not transmit CD 5P 5O transmit CD default disable space insertion default EP EO default EQ ER enable space insertion disable A -> X conversion enable A -> X conversion A-15
POSTNET Start Setup End Setup [[ [[ POSTNET Settings: Symbology Exclusive Enable Disable POSTNET (default disable) E7D E7B E7C note: setting any symbology to exclusive will disable all other symbologies A-16
Intelligent Mail Bar Code Start Setup End Setup [[ [[ Intelligent Mail Bar Code Settings: Symbology IMBC (default disable) Exclusive Enable Disable E6I E6G E6H note: setting any symbology to exclusive will disable all other symbologies A-17
GS1 DataBar Start Setup End Setup [[ [[ GS1 DataBar Settings: Symbology Exclusive Enable Disable GS1 DataBar Omnidirectional Truncated Stacked Stacked Omnidirectional (default enable) K: KY TK GS1 DataBar Limited (default enable) KK KZ TL GS1 DataBar Expanded Expanded Stacked (default enable) KL ES TM GS1 DataBar All Above Types (default enable) note: setting any symbology to exclusive will disable all other symbologies CDJ CD7 GS1 DataBar Check Digit (CD) GS1 DataBar AI Transmission
Korean Postal Authority Start Setup End Setup [[ [[ Korean Postal Authority Code Settings: Symbology Exclusive Enable Disable Korean Postal Authority (default disable) note: setting any symbology to exclusive will disable all other symbologies XJ not transmit CD +.
IATA Start Setup End Setup [[ [[ IATA Settings: Symbology IATA (default enable) Exclusive Enable Disable B5 C5 WI note: setting any symbology to exclusive will disable all other symbologies not check CD IATA Check Digit (CD) default check FC / SN only check FC / CPN / SN check FC / CPN / AC / SN IATA Check Digit (CD) Transmission not transmit CD transmit CD default A-20 5I 5J 5K 5L 5N 5M
Tri-Optic Start Setup End Setup [[ [[ Tri-Optic Settings: Symbology Tri-Optic (default enable) Exclusive Enable Disable KE K[ N/A note: setting any symbology to exclusive will disable all other symbologies A-21
Telepen Start Setup End Setup [[ [[ Telepen Settings: Symbology Telepen (default enable) Exclusive Enable Disable B: C: WH note: setting any symbology to exclusive will disable all other symbologies Telepen Conversion Output Mode numeric mode default ASCII mode A-22 E3 E!
JPN (Customer Bar Code) Start Setup End Setup [[ [[ JPN Settings: Symbology JPN (default disable) Exclusive Enable Disable E6S E6Q E6R note: setting any symbology to exclusive will disable all other symbologies A-23
PDF417 Start Setup End Setup [[ [[ PDF417 Settings: Symbology PDF417 (default enable) Exclusive Enable Disable CD! CDG CDS note: setting any symbology to exclusive will disable all other symbologies A-24
Micro PDF417 Start Setup End Setup [[ [[ Micro PDF417 Settings: Symbology Exclusive Enable Disable Micro PDF417 (default enable) CD5 CDH CDT note: setting any symbology to exclusive will disable all other symbologies A-25
Maxi Code Start Setup End Setup [[ [[ Maxi Code Settings: Symbology Exclusive Enable Disable Maxi Code (default enable) CD3 CDF CDR note: setting any symbology to exclusive will disable all other symbologies A-26
QR Code Start Setup End Setup [[ [[ QR Code Settings: Symbology QR Code (default enable) Exclusive Enable Disable CD2 CDE CDQ note: setting any symbology to exclusive will disable all other symbologies A-27
Micro QR Start Setup End Setup [[ [[ Micro QR Settings: Symbology Micro QR (default enable) Exclusive Enable Disable E!9 E3V E3W note: setting any symbology to exclusive will disable all other symbologies A-28
Aztec Code Start Setup End Setup [[ [[ Aztec Code Settings: Symbology Exclusive Enable Disable Aztec Code (default enable) CD6 CDI CDU note: setting any symbology to exclusive will disable all other symbologies A-29
Aztec Runes Start Setup End Setup [[ [[ Aztec Runes Settings: Symbology Aztec Runes (default disable) Exclusive Enable Disable CG5 CG3 CG! note: setting any symbology to exclusive will disable all other symbologies A-30
Data Matrix Start Setup End Setup [[ [[ Data Matrix Settings: Symbology Data Matrix (ECC 200) (default enable) Exclusive Enable Disable CD1 CDD CDP Data Matrix (ECC 000-140) (default disable) note: setting any symbology to exclusive will disable all other symbologies CH3 A-31 CH1 CH2
Codablock F Start Setup End Setup [[ [[ Codablock F Settings: Symbology Codablock F (default disable) Exclusive Enable Disable E5S E5Q E5R note: setting any symbology to exclusive will disable all other symbologies A-32
Chinese Sensible Code Start Setup End Setup [[ [[ Chinese Sensible Code Settings: Symbology Exclusive Enable Chinese Sensible Code (default disable) note: setting any symbology to exclusive will disable all other symbologies E5L A-33 E5M Disable E5N
All Codes Start Setup End Setup [[ [[ All Codes Settings: Symbology Exclusive Enable Disable All 1D Codes (default disable) CDB CDC CDN CDO CDZ CD[ C1 All 2D Codes (default disable) All 1D and 2D Codes (default disable) note: setting any symbology to exclusive will disable all other symbologies B1 Use this setting if you're having trouble reading a bar code with the default settings and you don't know what type of code you are trying to read.
Number of Characters Start Setup End Setup [[ [[ Number of Characters Settings: If you are going to read bar codes of a known length, it is recommended to set the scanner for a fixed number of characters. The scanner uses this to verify that labels read are of the correct length and reject labels that do not have the specified length.
Composite Codes Start Setup End Setup [[ [[ Composite Codes Settings: not ignore link flag for RSS/EAN-128 and EAN/UPC default Link Flag ignore link flag for RSS/EAN-128 and EAN/UPC RSS / EAN-128 disable RSS/EAN-128 composite Composite enable RSS/EAN-128 composite EAN / UPC Composite disable EAN/UPC composite default CIG CIF default E2X E2W enable EAN/UPC composite enable 1D composite only Composite Component enable 2D composite only enable 1D and 2D composites SR SQ default CM1 CM2 CM3 Out
String Options Start Setup End Setup [[ [[ Case Conversion Settings: no case conversion (AbCd -> AbCd) Case Conversion default convert to upper case (AbCd -> ABCD) convert to lower case (AbCd -> abcd) exchange case (AbCd -> aBcD) Z[ ZX ZY ZZ Output Format Settings: The following additional characters can be included in each code that is scanned: 1) Preamble / Postamble (up to 8 digits) Specified strings can be added in front and at the end of the data for all codes.
Prefix / Suffix Commands: Symbology Prefix Command Suffix Command SZ O2 N1 O3 N2 O! N3 O5 N! N5 ND N6 N7 N8 NC HM J9 O1 M9 NB N: YNY CME E6J S[ O7 P1 O8 P2 O9 P3 O: P! P5 QO P6 P7 P8 PC HN J: O6 M: PB P: YPY CMF E6K All Codes UPC-A UPC-A add-on UPC-E UPC-E add-on EAN-13 EAN-13 add-on EAN-8 EAN-8 add-on Code 39 Tri-optic Codabar Industrial 2 of 5 Interleaved 2 of 5 S-code Matrix 2 of 5 IATA MSI/Plessey Telepen UK/Plessey Code 128 GS1-128 Code 11 Intelligent Mail Bar Code A-38
Prefix / Suffix Commands Continued: Symbology Prefix Command Suffix Command E7E PF SS E5T NE CG1 E5O NL NM PD PE NH E7F QR ST E5U QP CG2 E5P QX QY QZ Q[ QS POSTNET GS1 DataBar Composite code Codablock-F Data Matrix Aztec Chinese Sensible Code QR Code Maxicode PDF417 MicroPDF417 Clear Prefix / Suffix Prefix / Suffix Example Programming Sequence: 1) Scan “Start Setup” 2) Scan “Prefix Command” or “Suffix Command” for the desired symbology 3) Scan up to 4 ASCII values from the Prefix / Suffix ASCII Value
Prefix / Suffix ASCII Value Table: ASCII Command ASCII Command ASCII Command ASCII Command ! “ # $ % & ' ( ) * + , .
Prefix / Suffix ASCII Value Table Continued: ASCII Command ASCII Command ASCII Command ASCII Command ^ _ ` { | } ~ 8E 8F 8G :U :V :W :X 0 1 2 3 4 5 6 7 8 9 R1 R2 R3 R! R5 R6 R7 R8 R9 R: (SUB) (ESC) (FS) (GS) (RS) (US) DEL 2[ :B :C :D :E :F :G Code Identification / Length Settings: code identification using Worth Data Code ID Code Identification code identification using AIM/ISO/IEC 15424 ID code length (1D/2D : 2/6 digit) Code Length code length (1D/2D : 6/6 digit) %3 %2 %! %7 Code Identification an
Worth Data Code ID Prefix / Suffix Values: Code Code ID Code Code ID UPC-A C MSI/Plessey Z UPC-A +2 F Telepen d UPC-A +5 G UK/Plessey a UPC-E D Code 128 T UPC-E +2 H GS1-128 T UPC-E +5 I Code 93 U EAN-13 B Code 11 b EAN-13 +2 L Korean Postal Authority c EAN-13 +5 M Intelligent Mail Bar Code 0 EAN-8 A POSTNET 3 EAN-8 +2 J GS1 DataBar y EAN-8 +5 K Composite Code-A m Code 39 V Composite Code-B n Code 39 Full ASCII W Composite Code-C l Italian Pharmace
Collective Reading Start Setup End Setup [[ [[ Collective Reading Settings: It is possible to not output data unless the specified number of codes is read. That means that the scanner does not read codes other than the specified number. Use this setting to read a group of labels all at once.
Collective Reading Settings Continued: disable same label read during multiple read default Same Label Read enable same label read during multiple read enable sorting decoded labels default E1W E1X default E1Y E1M E1Z Sorting Labels disable sorting decoded labels buffered mode (one image) Buffered Mode buffered mode (multiple images) non-buffered mode A-44 E1U E1V
Read Mode Start Setup End Setup [[ [[ Read Mode Settings: single read Read Mode default multiple read (see below) continuous read (used mainly for demonstration) T1 T2 T3 In multiple read mode, when a bar code has been decoded, the decoded data will be output and the scan engine will keep on reading. When the bar code that has just been output is read again, it will not be output.
Read Mode Settings Continued: Auto Trigger (Stand Mode) enable auto trigger disable auto trigger default disable auto trigger synchronization Auto Trigger Synchronization enable auto trigger synchronization default ,J ,G &R &S note: when the auto trigger is synchronized with the trigger switch, the read time configured for normal reading will be used for auto trigger read time.
Read Mode Settings Continued: read time 0 second read time 1 second read time 2 seconds default read time 3 seconds read time 4 seconds Normal Read Time read time 5 seconds read time 6 seconds read time 7 seconds read time 8 seconds read time 9 seconds read time * 10 read time indefinitely read 1 time, redundancy = 0 read 2 time, redundancy = 1 default read 3 time, redundancy = 2 read 4 time, redundancy = 3 Redundancy read 5 time, redundancy = 4 read 6 time, redundancy = 5 read 7 time, redundancy = 6
Read Mode Settings Continued: disable add-on wait more Add-on Delay Timer default add-on wait mode = 0.25 seconds add-on wait mode = 0.50 seconds add-on wait mode = 0.75 seconds YB YC YD YE Since WPC-type codes (UPC, EAN) with add-on (supplements) have a high probability of unsuccessful decoding, the scanner repeats decoding the add-on code during the specified period of time. It is effective to read the add-on parts, but it will also cause a reduced response when a code without an add-on is read.
Imager Settings: default E!B E!: E!C default E!D E!E E!F disable LED illumination Illumination Mode enable LED illumination LED illumination alternating disable laser aiming and LED illumination Aiming On/Off enable laser aiming disable laser aiming Central Reading enable central reading (read only a code that the laser aims at) disable central reading (read the entire image) E11 default careful mode (good for hard to read codes) 1D Code Decode Mode standard mode default semi-quick mode quick m
Indicator Settings Start Setup End Setup [[ [[ enable good read buzzer default Buzzer disable good read buzzer single tone buzzer Buzzer Tone default high-low buzzer low-high buzzer buzzer duration = 50ms default buzzer duration = 100ms Buzzer Duration buzzer duration = 200ms buzzer duration = 400ms buzzer loudness = maximum default buzzer loudness = high Buzzer Loudness buzzer loudness = medium buzzer loudness = low Buzzer Transmission buzzer before transmission default buzzer after transmis
Diagnostics Start Setup End Setup [[ [[ Diagnostic Codes: Transmit software version Transmit settings Transmit only changes from default Diagnostics Transmit ASCII printable string Transmit ASCII control string Reset to default (RS-232) Reset to default (USB-HID) A-51 [2 [! FBS [B ZW V3 TV
Appendix B Resolving USB Installation Issues The USB HID (Human Interface Device) keyboard driver is standard with Windows®. Most recent versions of Windows include necessary files in the installed Windows system folders so driver installation is easy if not automatic. It is possible for the user to cancel the HID driver installation before it is completed and this results in a problem. Restarting Windows does NOT initiate a re-installation; the user must go into the device management utility in Windows.
Windows 7 & Vista: 1. Go to the Start menu. 2. Select Control Panel. 3. Switch to Classic View if you are in Category View 4. Select System. 5. Select Hardware tab. 6. Select Device Manager 7. Double Click on Human Interface Devices 8. Locate the USB Human Interface Device with a ! in the icon. 9. Click on Update Driver 10. Follow instructions.